Contents 1. 2. 3. 4. 5. 6. 7. 8. INSTRUCTIONS FOR USE ................................................................ 4 SAFETY PRECAUTIONS ................................................................... 6 ENVIRONMENTAL RESPONSIBILITY ............................................... 8 USING THE HOB................................................................................ 9 CLEANING AND MAINTENANCE.................................................... 12 POSITION NEAR THE COUNTER TOP ................
General instructions 1. INSTRUCTIONS FOR USE THIS MANUAL CONSTITUTES AN INTEGRAL PART OF THE APPLIANCE. THIS MANUAL CONSTITUTES AN INTEGRAL PART OF THE APPLIANCE. IT SHOULD BE KEPT INTACT AND AT HAND FOR THE APPLIANCE’S ENTIRE LIFE CYCLE. IT IS IMPORTANT TO CAREFULLY READ THIS MANUAL AND ALL THE INSTRUCTIONS CONTAINED HEREIN BEFORE USING THE APPLIANCE. INSTALLATION MUST BE CARRIED OUT BY AUTHORIZED PERSONNEL AND COMPLY WITH THE REGULATIONS IN FORCE.
General instructions NEVER USE PANS OR GRIDDLE PLATES WHICH PROJECT BEYOND THE OUTSIDE EDGE OF THE HOB. SUITABLE HEAT-PROOF GLOVES SHOULD BE WORN FOR ALL OPERATIONS. DO NOT USE OR STORE FLAMMABLE MATERIALS IN THE APPLIANCE STORAGE DRAWER OR NEAR THIS APPLIANCE. THIS APPLIANCE IS DESIGNED FOR COOKING FOOD AND IT SHALL NOT BE USED AS A SPACE HEATER.
General instructions 2. SAFETY PRECAUTIONS REFER TO THE INSTALLATION INSTRUCTIONS FOR THE SAFETY REGULATIONS FOR ELECTRIC OR GAS APPLIANCES AND VENTILATION FUNCTIONS. IN YOUR INTERESTS AND FOR YOUR SAFETY THE LAW REQUIRES THAT THE INSTALLATION AND SERVICING OF ALL ELECTRICAL APPLIANCES IS CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE. OUR APPROVED INSTALLERS GUARANTEE A SATISFACTORY JOB. GAS OR ELECTRICAL APPLIANCES MUST ALWAYS BE DISCONNECTED BY SUITABLY SKILLED PEOPLE.
General instructions DO NOT LET CHILDREN GO NEAR THE APPLIANCE WHEN IT IS IN OPERATION OR PLAY WITH IT AT ANY TIME. DO NOT INSERT POINTED METAL OBJECTS (CUTLERY OR UTENSILS) INTO THE SLITS IN THE APPLIANCE. DO NOT USE STEAM JETS FOR CLEANING THE APPLIANCE. THE STEAM COULD REACH THE ELECTRONICS, DAMAGING THEM AND CAUSING SHORT-CIRCUITS. DO NOT MODIFY THIS APPLIANCE. DO NOT SPRAY ANY SPRAY PRODUCTS NEAR THE ELECTRICAL APPLIANCE WHILE IT IS IN OPERATION.
Instructions for disposal 3. ENVIRONMENTAL RESPONSIBILITY Our products packing is made of non-polluting materials, which are therefore compatible with the environment and recyclable. Please help by disposing of the packaging correctly. You can obtain the addresses of collection, recycling and disposal centres from your retailer or from the competent local organisations. Do not discard the packaging or any part of it, or leave it unattended.
Instructions for the user 4. USING THE HOB 4.1 Lighting the hob burners Before lighting the hob burners, check that the flame-spreader crowns are correctly in place with their respective burner caps, making sure that the holes A in the flame-spreaders are aligned with the igniters and thermocouples. The burner controlled by each knob is shown next to the knob. The appliance is equipped with an electrical ignition device.
Instructions for the user 4.2 Practical tips for using the burners For better burner efficiency and to minimise gas consumption, use pans with a flat, smooth base and a lid that have a suitable size for the burner, thus preventing the flames reaching the sides of the pan (see paragraph “4.3 Pan Diameter”). Once the contents come to the boil, turn down the flame far enough to prevent the liquid from boiling over.
Instructions for the user HOB BURNER 1 Auxiliary 2 Semi rapid 5 Ultra-rapid Ø min. and max. (in cm) 12 - 20 16 - 24 20 - 26 The following are the diameters of the pans that can be used with the raised pan stand: Ø min. and max. (in cm) 16 - 26 22 - 26 26 - 34 HOB BURNER 1 Auxiliary 2 Semi rapid 5 Ultra-rapid HOB BURNER 1 Auxiliary 3 Reduced rapid 6 Dual control Ø min. and max.
Instructions for the user 5. CLEANING AND MAINTENANCE Before performing any operations requiring access to powered parts, switch off the power supply to the appliance. NEVER USE A STEAM JET FOR CLEANING THE APPLIANCE. 5.1 Cleaning stainless steel To keep stainless steel in good condition it should be cleaned regularly after use. Let it cool first. 5.1.
Instructions for the user In models with central pan stand, fit this piece, taking care that its centre is perfectly aligned with the centre of the burner In models equipped with pan stands, fit as shown in the figure, taking care to position them exactly as shown. Refer to the enlarged details in the figure below for guidance.
Instructions for the user 5.3 Preventive Maintenance This appliance does not need any special maintenance. However, a few simple operations have to be carried out periodically to prevent malfunctioning; Burners: the burners must be cleaned periodically to ensure correct conbustion make sure that all the openings and flame ports are clean and free of obstacles, and the burners rest firmly on their supports. Gas connection: the gas connection must be checked periodically.
Instructions for the installer 6. POSITION NEAR THE COUNTER TOP The following operation requires building and/or carpentry work so must be carried out by a competent tradesman. Installation can be carried out on various materials such as masonry, metal, solid wood or plastic laminated wood as long as they are heat resistant (T 90°C). 6.1 Fixing to a support structure model with traditional casing (fig.
Instructions for the installer PGA64 PSA906 PGA75SC3 PGA95SC3 (only “906” models) PGA32 51 31 0,8 0,8 3,3 29 2 16 73 49 4
Instructions for the installer 6.2 Fixing to the electric model support structure Create an opening with the dimensions shown in the figure in the top surface of the counter, keeping a minimum distance of 50 mm from the rear edge. The lower part of the casing must be fully accessible after the appliance has been installed.
Instructions for the installer PGA64F PSFA906 PGA75F3 - PGA75FSC3 3) PGA95F3 - PGA95FSC3 4) (only “906” models) If laminated surfaces are used, it is advisable to spread a layer of anti-infiltration “primer” across the milled surface.
Instructions for the installer Obstructions: location of gas and electric connectors (measured in mm). PGA64F PGA75F3 - PGA75FSC3 PGA95F3 - PGA95FSC3 PSFA906 PGA32 24,7 31,5 228 122 14,2 480 Precautions: the temperature of the inside surface of the hob may exceed 125°C. To avoid any hazardous situations, over-the-hob access must be restricted. Refer to the installation instructions.
Instructions for the installer IMPORTANT: if the appliance is mounted on a unit, make sure that a separating shelf is installed, as shown in the figure. However, if the appliance is on an oven installed under the hob, there is no need to install a separating shelf. If installed on top of an oven, the latter must be equipped with a cooling fan.
Instructions for the installer 6.3 Clearances above and around domestic appliances Extract from AS5601 REQUIREMENTS 1 Overhead clearances – (Measurement A) Range hoods and exhaust fans shall be installed in accordance with the manufacturer’s instructions. However, in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or, for an overhead exhaust fan, 750 mm.
Instructions for the installer NOTES 1 2 3 4 5 6 6.4 Requirement 3 does not apply to a freestanding or elevated cooking appliance which is designed to prevent flames or the cooking vessels from extending beyond the periphery of the appliance. The ‘cooking surface area’ is defined as that part of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs. For definition of hob, see Clause 1.4.64. For definition of trivet, see Clause 1.4.109.
Instructions for the installer 6.5 Gas connection This appliance is suitable for installation with Natural Gas or ULPG (propane/butane). Refer to page 25 for the relevant burner pressure and appropriate injector sizes. When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to the gas inlet. A test point (for checking the gas pressure) is supplied either with the regulator or as a separate fitting in the case of ULPG (propane) appliances.
Instructions for the installer Installation with the flexible hose must be carried out so that the length of the piping does not exceed 2 metres fully extended; make sure that the hoses do not come into contact with moving parts and that they are not crushed in any way. 6.6 Connection to liquid gas Use a pressure regulator and make the connection on the gas cylinder following the guidelines established by the regulations in force.
Instructions for the installer 7. ADAPTATION TO DIFFERENT TYPES OF GAS Before carrying out the following operations, disconnect the appliance from the power supply. The appliance is preset for natural gas NG at a pressure of 1.0 kPa. In the case of operation with other types of gas, the burner nozzles must be changed and the minimum flame adjusted on the gas taps. To change the nozzles, proceed as described in the following paragraphs. 7.
Instructions for the installer 7.2 Burner and nozzle characteristics table Burner Auxiliary (1) Semi rapid (2) Reduced rapid (3) Rapid (4) Ultra rapid (5) Dual control (6) ULPG – 2.75 kPa Nominal gas Consumption (MJ/h) 3.9 6.3 9.0 10.8 15.0 3.2 13.6 Burner Auxiliary (1) Semi rapid (2) Reduced rapid (3) Rapid (4) Ultra rapid (5) Dual control (6) 26 Injector (mm) 0.54 0.68 0.85 0.88 1.05 Centre 0.50 Outer 0.72 + 0.72 NG – 1.0 kPa Nominal gas Consumption (MJ/h) 3.9 7.5 9.0 12.0 15.0 3.6 15.
Instructions for the installer 7.
Instructions for the installer 8. FINAL OPERATIONS After making the adjustments described above, reassemble the appliance by following in reverse the instructions reported in paragraph "7.1 Replacement of the cooking hob nozzles". After adjustment with a gas other than the preset one, replace the label on the casing of the appliance with the label corresponding to the new gas. This label can be obtained from the nearest Authorised Service Centre. 8.