Instruction manual
EN
3
INSTALLATION INSTRUCTIONS:
Thehoodissuppliedwithalltheaccessoriesnecessaryfor
itsinstallation.Theminimumdistancebetweenthelower
surfaceofthehoodandthehobmustbeatleast750mm
for gas hobs and 650mm for electric hobs (Fig. 1 ). If
themotorinletis equippedwithanon-return valvefor
fumes,makesureitcanopenandclosefreely.
Foreasyinstallationitisrecommendedtofollowtheprocedures
describedbelow:
1) Thehoodmustbecentredwithrespecttothehobsurface.
2) There are different installation procedures depending on
thehoodmodel.Chooseoneofthefollowingxingsystems
(Fig.2):
a) 2 levelling hooks that fasten on with the supplied
expansionplugs
b) Rearlevellingbracketthatfastensonwiththesupplied
expansionplugs
c) Levellinganchorsonmotorboxthatfastenonwiththe
suppliedexpansionplugs
d) For island models refer to the special installation
attachment.
N.B.:Fixingsystemsa)andb)tontothebackofthehood
intheholesL1(Fig.4).
3) Removethegreaseltersandpositionthehoodonthewall
andmarkthereferencepositionfortheholestoanchorthe
relativexingsystem.
4) Drillthe2holespreviouslymarkedafterremovingthehood
fromthewall
5) Anchor the xing system to the wall by tightening the
expansionplug
6) MarkholesL2onthewalltosecuretheplugssafelyinthe
holes.(plugssupplied)
7) Hang the hood on the xing system (g. 2) and level it
usingtheadjustmentscrews(g.2).
8) Securelyxthehoodbyfullytighteningthetwoexpansion
screwsoftheholesL2
AIRCONNECTIONSYSTEMS:
EXTRACTION version: Connect the fume expulsion duct
(insidediameter150mm.)totheexhaustofthemotorinlet.
IftheexpulsionductisD.120mm,usethespecialreduction
ange (F) supplied, where applicable. The expulsion duct
mustnothaveadiameteroflessthan120mm.
Note that if thehood is supplied with an active carbon
lter,thismustberemoved(seepage8)
DeviationforGermany:
Whenthehoodandotherappliancespoweredbyenergyother
thanelectricityaresimultaneouslyON,thenegativepressure
intheroommustnotexceed4Pa(4x10-5bar).