Digital Pressure Switch Low profile RoHS compliant 9.8 mm (Actual size) Vertical mounting space reduced to approx. ! 53.4 mm 103.5 mm 12 26.1 mm Reduced in depth! Can copy up to 10 switches simultaneously. The settings of the master pressure switch (source of copy) can be copied to the slave pressure switches.
Improved visibility from multiple directions The vacuum suction and burst pressure can be checked at a glance by indicator lights. Multi-angle indicator 100 kPa OUT2 threshold Red light ON OUT2 Vacuum burst pressure Green light ON OUT1 Suction pressure 0 OUT1 threshold Green light ON : OUT1 output Red light ON : OUT2 output -100 kPa Mounting Direct mounting Panel mounting DIN rail mounting Can be mounted closely in vertical direction.
Digital Pressure Switch Series ZSE10(F)/ISE10 How to Order Rated pressure range ISE10 –0.100 to 1.000 MPa For positive pressure ISE10 M5 A M For vacuum/ compound pressure ZSE10 M5 B M Option 3 Rated pressure range ZSE10 ZSE10F Symbol Calibration certificate — — 0.0 to –101.0 kPa –100.
Series ZSE10(F)/ISE10 Specifications ZSE10 (vacuum pressure) ZSE10F (compound pressure) ISE10 (positive pressure) Rated pressure range 0.0 to –101.0 kPa –100.0 to 100.0 kPa –0.100 to 1.000 MPa Set pressure range/Pressure display range 10.0 to –105.0 kPa –105.0 to 105.0 kPa –0.105 to 1.050 MPa Withstand pressure 500 kPa 500 kPa 1.5 MPa Minimum unit setting 0.1 kPa 0.1 kPa 0.
Digital Pressure Switch Series ZSE10(F)/ISE10 Analogue Output Analogue output [V] Voltage output 5 Range Rated pressure range A B C For vacuum pressure 0.0 to –101.0 kPa — 0 –101 kPa For compound pressure –100.0 to 100.0 kPa — –100 kPa 100 kPa For positive pressure –0.100 to 1.000 MPa –0.1 kPa 0 1 MPa 1 0.6 AB C Pressure Descriptions button (DOWN) Output (OUT1) indicator (Green) Lights up when switch output (OUT1) is turned ON.
Series ZSE10(F)/ISE10 Dimensions ZSE10(F)/ISE10 M5 (30) 2 x 3.3 M5 x 0.8 25 13 1.2 (12) 3.5 9.8 4.2 (7.7) 6.4 51.8 ZSE10(F)/ISE10 M5 x 0.8 25 1.2 4.5 M5R 6.4 51.8 4 4.2 9.
Digital Pressure Switch ZSE10(F)/ISE10 Series ZSE10(F)/ISE10 01 13 25 Width across flats 10 1.2 2 x 3.3 8 3.5 12.5 51.8 9.8 4.2 6.4 R1/8 11 ZSE10(F)/ISE10 N01 NPT1/8 25 8 3.5 51.8 4.2 13 9.8 6.4 12.5 Width across flats 12 13 1.2 2 x 3.
Series ZSE10(F)/ISE10 Dimensions ZSE10(F)/ISE10 M5 D Panel mount adapter + Front protective cover 51.8 4.2 10.5 Panel thickness 0.5 to 5 3 M5 x 0.8 26.1 6.5 (67) 10.2 17.4 73.4 17.5 17.8 64.6 ZSE10(F)/ISE10 M5R D Panel mount adapter + Front protective cover 21.4 10.2 M5 x 0.8 51.8 73.4 6 17.5 17.8 64.6 4.2 Panel thickness 0.5 to 5 6.5 26.1 3 (67) 17.
Digital Pressure Switch Series ZSE10(F)/ISE10 57.2 0 –0.4 57.2 0 –0.4 4 x R 2 or le ss 14.8 0 –0.4 Panel fitting dimensions 28.8 or more (Rear ported) 14.8 x n pcs. + 3 x (n pcs. – 1) For side ported models, dimensions differ depending on the fittings and tubing. 4 x 3 R or ss le M5 ZSE10(F)/ISE10 R With DIN rail 25 5 3.5 4.3 9.5 (35) 51.8 4.2 53.5 6.4 The DIN rail needs to be prepared by the customer. M5 x 0.8 1.2 9.
Series ZSE10(F)/ISE10 Function Details A Copy function (F97) The settings of the master pressure switch can be copied to the slave pressure switches. This can reduce the labour for setting and prevent the entry of incorrect set-values. The set-value can be copied to up to 10 switches simultaneously. (Maximum communication distance 4 m) 1 switch 2 switches Master 10 switches Slave (Max.
Digital Pressure Switch Series ZSE10(F)/ISE10 The F in ( ) shows the function code number. Refer to the Operation Manual for the details of operation procedures and function codes. G Error indication function Error name Error code Remedy Description Load current of switch output (OUT1) exceeds 80 mA. Overcurrent error Turn the power off and remove the output factor for the over current. Then turn the power on. Load current of switch output (OUT2) exceeds 80 mA.
Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) Note 1), and other safety regulations. Note 1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Safety Instructions Caution 1. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
Series ZSE10(F)/ISE10 Specific Product Precautions 1 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC Products (M-E03-3) for Precautions. Handling Warning 1. Do not use pressure sensors with corrosive and/or flammable gases. Caution 1. Do not drop, bump, or apply excessive impacts (100 m/s2) while handling. Although the body of the sensor may not be damaged, the internal parts of the sensor could be damaged and lead to a malfunction.
Series ZSE10(F)/ISE10 Specific Product Precautions 2 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC Products (M-E03-3) for Precautions. Mounting Caution 2. Removal and mounting of DIN rail • It is necessary to prepare a DIN rail adapter for the mounting of the DIN rail. • Take care not to bend the claws of the DIN rail adapter when mounting.
Series ZSE10(F)/ISE10 Specific Product Precautions 3 Be sure to read before handling. Refer to back pages 1 and 2 for Safety Instructions and Handling Precautions for SMC Products (M-E03-3) for Precautions. Set Pressure Range and Rated Pressure Range Caution Set the pressure within the rated pressure range. The set pressure range is the range of pressure that is possible in setting. The rated pressure range is the range of pressure that satisfies the specifications (accuracy, linearity, etc.