Datasheet
Series SY3/5/7/9000
Valves
Page 61
PDF AVAILABLE ONLINE
CATALOGUE ES11-83A AVAILABLE
CAD CD-ROM AVAILABLE
Base Mounted Valves
Single Unit
Accessories for Base Mounted SY Valves
Specifications
Response Time
Solenoid Specifications
Sinlge Subbase part no.
SY3000-27-1F-Q
SY5000-27-1F-Q
SY7000-27-1F-Q
SY7000-27-2F-Q
SY9000-27-1F-Q
SY9000-27-2F-Q
Valve type
SY3*40 valves
SY5*40 valves
SY7*40 valves
SY7*40 valves
SY9*40 valves
SY9*40 valves
Subbase part size
G 1/8
G 1/4
G 1/4
G 3/8
G 3/8
G 1/2
Electrcal connectors are common to SY body ported valves.
SY3000
SY7000
SY5000
SY9000
Series
Fluid
Internal pilot
Operating pressure
range (MPa)
External pilot
Operating pressure
range (MPa)
Ambient and fluid temperature (˚C)
Max. operating
frequency (Hz)
Manual override
(Manual operation)
Pilot exhaust method
Mounting orientation
Enclosure
SY3000 SY5000 SY7000
Air
0.1 to 0.7
0.2 to 0.7
-100 kPa to 0.7
0.25 to 0.7
0.25 to 0.7
0.25 to 0.7
-10 to 50 (No freezing)
10
3
5
3
Pilot valve individual exhaust
Common exhaust type for main and pilot valve
Lubrication
Not required
Unrestricted
Dustproof (∗ DIN terminal, M8 connector conforms to IP65)
5
3
SY9000
5
3
2 position single
2 position double
3 position
Operating pressure range
Pilot
pressure
range
2 position double
2 position single
3 position
2 position single, double
3 position
Internal pilot
External pilot
Non-locking push type,
Push-turn locking slotted type, Push-turn locking lever type
0.15 to 0.7
Type of
actuation
Without light/surge
voltage suppressor
12 or less
With light/surge voltage suppressor
Response time (ms)
(at the pressure of 0.5 MPa)
Type UType Z
12 or less15 or less
2 position single
10 or less 10 or less13 or less
2 position double
15 or less 16 or less20 or less
3 position
Type of
actuation
Without light/surge
voltage suppressor
19 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type UType Z
19 or less26 or less
2 position single
18 or less 18 or less22 or less
2 position double
32 or less 32 or less38 or less
3 position
Type of
actuation
Without light/surge
voltage suppressor
31 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type UType Z
33 or less38 or less
2 position single
27 or less 28 or less30 or less
2 position double
50 or less 50 or less56 or less
3 position
Type of
actuation
Without light/surge
voltage suppressor
35 or less
Response time (ms)
(at the pressure of 0.5 MPa)
Type UType Z
35 or less41 or less
2 position single
35 or less 35 or less41 or less
2 position double
62 or less 62 or less64 or less
3 position
Electrical entry
Coil rated voltage (V)
Allowable voltage fluctuation (%)
Power consumption (W)
Apparent power
Surge voltage suppressor
Indicator light
DC
DC
AC Hz
50
60
AC
100 V
200 V
110 V
220 V
[230 V]
Grommet (G), (H)
L plug connector: L
M plug connector: M
DIN terminal (D) (Y)
M8 connector (W)
24, 12, 6, 5, 3
100, 110, 200, 220
∗
±10% of rated voltage
0.1 (With indicator light only)
0.35 (with indicator light: 0.4 DIN terminal with indicator light: 0.45)
2.5 (With indicator light: 2.6)
2.7 (With indicator light: 2.8)
2.3 (With indicator light: 2.4)
1.6 (With indicator light: 1.7)
1.4 (With indicator light: 1.5)
Diode (Varistor is for DIN terminal and Non-polar type.)
LED (AC of DIN terminal is neon bulb.)
Standard
With power saving circuit
With light/surge voltage suppressor
With light/surge voltage suppressor
With light/surge voltage suppressor