Datasheet

How to Order
Dimensions
G36
G46
G36 L
Size
Maximum display
Outside diameter
ø37.5
ø42.5
Symbol
36
46
Clear cover material
Material
Polycarbonate
Nylon
Symbol
N
Made to order specification
Specification
With MPa/psi units
Symbol
X30
Note)
Connection thread
Colour zone type
Size
R1/8
R1/4
Body size
G36
G46
Symbol
01
02
Note) This will no longer be sold
for use in Japan after the
new Weight and Measure
Act is implemented.
(Only SI units are used for
the Japanese market.)
Unit
0.2 MPa
0.4 MPa
1.0 MPa
0.2 MPa, 30 psi
0.4 MPa, 60 psi
1.0 MPa, 150 psi
Symbol
2
4
10
P2
Note)
P4
Note)
P10
Note)
Note) This symbol must be
used with Option “X30”.
The dimensions in ( ): Connecting thread R1/4
Green zone
Red zone
Red zone
Setting pointer (Red)
Green zone Red zone
Red zone
41.5 (45.5)
25.5
R1/8
(R1/4)
Clear cover
• Polycarbonate part no.: G46-00-00-3
• Nylon part no.: G46-00-00-3N
ø42.5
12 (14)
41.5
24.5
R1/8
ø37.5
12
Clear cover
• Polycarbonate part no.: G36-00-00-3
• Nylon part no.: G36-00-00-3N
0110
Series G36-L, G46-L
Procedure for Setting the Limit Gauge Indicator / Colour Zone Type
(1) Before setting the (red) colour zone, turn the cover
counterclockwise (approximately 6 to 7 mm) until it stops.
Then, remove by pulling it towards you.
(2) Use a pen tip to set the (red) colour zone indicator.
Be careful not to bend the other needle or damage the dial
plate.
(3) After completing the setting, replace the cover.
Fit the cover by aligning the cutout in the cover to the groove
on the top of the black case. Turn the cover clockwise
(approximately 6 to 7 mm) until it stops. Make sure that the
matching mark on the cover is aligned with the groove on the
top of the case.
Selection
Precautions
Mounting
1.
During transport and installation, do not apply
shock to the product, such as dropping. Doing
so will affect its precision.
2.
Regarding the installation posture, place it
perpendicular to the ground, with the zero point on
the reading of the pressure gauge
facing down.
3.
Do not install it in areas that are exposed to high
temperatures or humidity, because doing so will
lead to improper operation.
4.
To screw in the pressure gauge, make sure to turn
the gauge by placing a wrench over the square
wrench flats.
If the pressure gauge is screwed in by holding it on some
other area, air leakage or damage may result.
1.
Make sure that no direct impact or vibrations are
applied to the body.
2.
If operating under pressure pulsations or under
high frequency operations, please contact SMC.
Be sure to read before handling.
Refer to Precautions for Handling Pneumatic
Devices (M-03-E3A) for Safety Instructions and
Common Precautions.
Series G36-L, G46-L
Pressure Gauge with Limit Indicator
Colour Zone Type
Turn counterclockwise
Pull
Cover
Colour zone
Pen tip
Top hollow
Slit
Mark
Caution
Caution
2