Datasheet

Note) When “n” is an odd number, an even number that is one larger than this
odd number is used for the calculation. However, the minimum even
number is 4. So, 4 is used for the calculation when “n” is 1 to 3.
Since the operating range is provided as a guideline including hysteresis, it
cannot be guaranteed. (Assuming approximately ±30% dispersion.) It may
vary substantially depending on an ambient environment.
[mm]
[mm]
12
Auto Switch Rail Mounting
-XC13
Symbol
Auto switch model
Number of auto switches
1
2
Same surface
n (n: No. of auto switches)
Same surface
D-M9/M9V
D-F7V
D-J79C
55
10 + 10 (n – 2)
(n = 4, 6 ···)
Note)
D-M9WV
D-M9AV
D-F7WV
D-F7BAV
D-A79W
10 15
10 + 15 (n – 2)
(n = 4, 6 ···)
Note)
D-M9W
D-M9A
10 15
15 + 15 (n – 2)
(n = 4, 6 ···)
Note)
D-F7
D-J79
55
15 + 15 (n – 2)
(n = 4, 6 ···)
Note)
D-F7W/J79W
D-F7BA
D-F79F/F7NT
10 15
15 + 20 (n – 2)
(n = 4, 6 ···)
Note)
D-A7/A80
D-A7H/A80H
D-A73C/A80C
510
15 + 10 (n – 2)
(n = 4, 6 ···)
Note)
D-A7H
D-A80H
510
15 + 15 (n – 2)
(n = 4, 6 ···)
Note)
Auto switch model
Bore size
20 25 32 40 50 63 80 100
D-M9/M9V
D-M9W/M9WV
D-M9A/M9AV
4 4 5 4 5.5 6.5 7.5 7
D-F7/F79F/F7V
D-J79/J79C
D-F7W/J79W/F7WV
D-F7BA/F7BAV
D-F7NT
4.544.555666
D-A7/A80
D-A7H/A80H
D-A73C/A80C
9 9 10 11 11 13.5 13 13.5
D-A79W
11 11 13 14 14 16.5 16 16.5
Auto switch model
Bore size [mm]
ø
20 to ø100
D-M9/M9V
D-M9W/M9WV
BQ2-012
D-M9A/M9AV
BQ2-012S
Note 1) When ordering the auto switches other than D-M9첸첸첸 mentioned on
the above and D-F7BA(V), order auto switch mounting brackets BQ-1
separately.
Note 2) When adding D-M9A(V), order a stainless steel screw set BBA2 together
with BQ2-012S separately.
When adding the auto switch D-F7BA(V), order a stainless steel screw set
BBA2 separately.
Auto Switch Mounting Brackets/Part No.
Minimum Stroke for Auto Switch Mounting
Operating Range
61
Series CG1