47
Series CG1
[mm]
Values which include hysteresis are for guideline purposes only, they are not a guarantee (assuming approximately ±30% dispersion) and may change
substantially depending on the ambient environment.
Other than the applicable auto switches listed in “How to Order”, the following auto switches are mountable.
Refer to the Auto Switch Guide for the detailed specifi cations.
With pre-wired connector is also available for solid state auto switches. For details, refer to the Auto Switch Guide.
Normally closed (NC = b contact) solid state auto switches (D-F9G/F9H) are also available. For details, refer to the Auto Switch Guide.
Wide range detection type, solid state auto switch (D-G5NB) is also available. For details, refer to the Auto Switch Guide.
st: Stroke [mm]
Trunnion type is not available for ø80 and ø100.
Auto switch model
Bore size
20 25 32 40 50 63 80 100
D-M9(V)
D-M9W(V)
D-M9A(V)
4.5 5.0 4.5 5.5 5.0 5.5
D-A9
768889
D-C7/C80
D-C73C/C80C
8 10 9 10 10 11
D-B5/B64
8 10 9 10 10 11 11 11
D-B59W
13 13 14 14 14 17 16 18
D-H7/H7W
D-H7NF/H7BA
4 4 4.5 5 6 6.5
D-H7C
7 8.5 9 10 9.5 10.5
D-G5/G5W/G59F
D-G5BA/K59/K59W
4 4 4.5 5 6 6.5 6.5 7
D-G5NT
4 4 4.5 5 6 6.5 6.5 7
D-G5NB
35 40 40 45 45 45 45 50
Auto switch model
Basic, Foot, Flange, Clevis Trunnion
With 1 pc.
(Rod cover side)
With 2 pcs.
(Different surfaces)
With 2 pcs.
(Same surface)
With 1 pc.
(Rod cover side)
With 2 pcs.
(Different surfaces)
With 2 pcs.
(Same surface)
Auto switch mounting
surface
Auto switch type
Port surface Port surface Port surface
D-M9(V)
D-M9W(V)
D-M9A(V)
D-A9
10 st or more 15 to 44 st 45 st or more 10 st or more 15 to 44 st 45 st or more
D-C7/C8
10 st or more 15 to 49 st 50 st or more 10 st or more 15 to 49 st 50 st or more
D-H7/H7W
D-H7BA/H7NF
10 st or more 15 to 59 st 60 st or more 10 st or more 15 to 59 st 60 st or more
D-C73C/C80C/H7C
10 st or more 15 to 64 st 65 st or more 10 st or more 15 to 64 st 65 st or more
D-B5/B6/G5/K5
D-G5W/K59W/G5BA
D-G59F/G5NT
10 st or more 15 to 74 st 75 st or more 10 st or more 15 to 74 st 75 st or more
D-B59W
15 st or more 20 to 74 st 75 st or more 15 st or more 20 to 74 st 75 st or more
Type Model Electrical entry Features Applicable bore size [mm]
Solid state
D-H7A1, H7A2, H7B
Grommet (In-line)
ø20 to ø63
D-H7NW, H7PW, H7BW Diagnostic indication (2-colour indication)
D-H7BA Water resistant (2-colour indication)
D-G5NT With timer ø20 to ø100
Reed
D-C73, C76
ø20 to ø63
D-C80 Without indicator light
D-B53 ø20 to ø100
Operating Range
Cylinder Mounting Bracket, by Stroke/Auto Switch Mounting Surfaces