Compact Cylinder New ISO Standards [ISO/21287] It is possible to mount small auto switches on 4 surfaces. Auto switches can be mounted on any of the 4 surfaces, depending on the installation conditions. Improved flexibility of system design. 2-color indication solid state auto switch Appropriate setting of the mounting position can be performed without mistakes. Operating range ON OFF Red Green Red Proper operating range The green light lights up at a proper operating range.
ISO Standards [ISO/21287] Compact Cylinder Series C55 ø20,ø25,ø32,ø40,ø50,ø63,ø80,ø100 How to Order C55 B 20 10 With auto switch CD55 B 20 10 M9B S Number of auto switches With auto switch (Built-in magnet) Nil S n 2 pcs. 1 pc. “n” pcs.
ISO Standards [ISO/21287] Compact Cylinder Series C55 Specifications Pneumatic (Non-lube) Double acting, Single rod Air 1.5 MPa 1.0 MPa 0.05 MPa (ø20 to ø63), 0.03 MPa (ø80, ø100) Without auto switch: –10 to 70°C (No freezing) With auto switch: –10 to 60°C (No freezing) Rubber bumper on both end +1.
Series C55 Allowable Lateral Load Allowable Kinetic Energy Make sure to operate strictly within the allowable lateral load range to the rod end. Make sure to operate strictly within the allowable range of the load weight and maximum speed. Operation outside of this range may result in shorter service life or damage to the device. Operation outside of this range may cause excessive impact, which may result in the damage to the device.
ISO Standards [ISO/21287] Compact Cylinder Series C55 Construction ø20, ø25 !1 M: Rod end male thread With auto switch (Built-in magnet) i r t !2 !4 y e q !3 o w u ø32 to ø63 !0 With auto switch (Built-in magnet) !2 r t !4 y i e q !3 o w u ø80, ø100 !0 With auto switch (Built-in magnet) !2 r t !4 y i q e !3 w u Component Parts No.
Series C55 Mounting Bolt Should use recommended bolt shown as below table when mounting the cylinder using through-hole. Mounting bolt OA thread Note) To install a through-hole type mounting bolt, bore size 20 to 100 mm, make sure to use the flat washer that is provided.
ISO Standards [ISO/21287] Compact Cylinder Dimensions Series C55 [First angle projection] ø20, ø25 øD T F Flat washer 4 pcs. 2 øI ø20 OA (4 positions) (The same four-place size) 2 x 4 x RA 5.5 H thread effective depth C M Q øOB counterbore RB (4 positions) (The same four-place size) øN through (4 positions) (The same four-place size) Auto switch E M5 x 0.
Series C55 Dimensions [First angle projection] ø32 to ø63 øD Flat washer 4 pcs.
ISO Standards [ISO/21287] Compact Cylinder Dimensions Series C55 [First angle projection] ø80, ø100 M12 x 1.75 effective depth 21 Auto switch Q F øI M10 x 1.5 effective depth 15 (4 positions) (The same four-place size) 10 B + Stroke A + Stroke ø8.4 through (4 positions) (The same four-place size) C Z M E øD C 2 x G1/8 K M 2.5 E ø13.5 counterbore 5 (4 positions) (The same four-place size) M: Rod end male thread Width across flats K M16 x 1.
Series C55 Mounting Bracket [First angle projection] Foot bracket Flange bracket Hexagon socket head cap screw (Accessory) FL 4 x øFD 2 x øFD 2 x øLD 1 H1 FX M FZ Hexagon socket head cap screw (Accessory) øD LT L LH M/2 R M LX LZ Y X FY FT M ø32 to ø100 ø20, ø25 FV (mm) (mm) Bore size (mm) L LD LH LT LX 20 25 32 40 50 63 80 100 22 22 24.5 26 31 31 38.5 45 7 7 7 10 10 10 12 14.5 27 29 33.
ISO Standards [ISO/21287] Compact Cylinder Proper Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height Reed auto switch Solid state auto switch D-A9 D-M9 D-M9 W D-M9 AL D-P3DW Series C55 [First angle projection] B W B W A ≈ Hs ø20, ø25 A ≈ Hs ø32, ø40, ø50, ø63, ø80, ø100 ∗ Figures in the table below are used as a reference when mounting the auto switches for stroke end detection.
Series C55 The Number of Surfaces and Grooves Where an Auto Switch Can Be Mounted (As Direct Mounting) The number of the surfaces and grooves where the auto switch can be mounted, by switch type, are shown in the table below. Piping port A D Auto switch model Bore size (mm) B D-A9 , M9 A (Mounting groove no.) (Mounting groove no.
ISO Standards [ISO/21287] Compact Cylinder Series C55 Mounting of Auto Switch/Direct Mounting Style To mount auto switches, follow the instruction illustrated below. Solid state······D-M9 (V) D-M9 W(V) D-M9 A(V) Reed···············D-A (V) Solid state······D-P3DW ø20 to ø100 ø20 to ø100 Hexagon socket head cap screw (M2.5 x 9 L) Watchmakers screw driver Protrusion Hexagon socket head cap screw (M2.
Prior to Use Auto Switches Common Specifications 1 Specific Product Precautions Before handling auto switches, refer to “Handling Precautions for SMC Products” (M-E03-3) for Auto Switches Precautions. Auto Switches Common Specifications Type Reed auto switch Operating time Impact resistance 1.
Prior to Use Auto Switches Common Specifications 2 Specific Product Precautions Before handling auto switches, refer to “Handling Precautions for SMC Products” (M-E03-3) for Auto Switches Precautions. Auto Switch Hysteresis Contact Protection Box: CD-P11, CD-P12 Hysteresis is the distance between the position at which piston movement operates an auto switch to the position at which reverse movement turns the switch off. This hysteresis is included in part of the operating range (one side).
Prior to Use Auto Switches Connection and Example Basic Wiring Solid state 3-wire, NPN Solid state 3-wire, PNP Brown Brown Brown 2-wire (Reed switch) 2-wire (Solid state) Brown Load Load Main curcuit of switch Main curcuit of switch Black Black Load Blue Load Indicator protection circuit, etc. Main curcuit of switch Blue ~ Blue Blue Brown Brown (Power supply for switch and load are separate) Brown Load Main curcuit of switch Indicator protection circuit, etc.
Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) For details about certified products conforming to international standards, visit us at www.smcworld.com. Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA). Flexibility is 1.5 times greater than the conventional model (SMC comparison). Using flexible cable as standard spec.
2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) For details about certified products conforming to international standards, visit us at www.smcworld.com. Auto Switch Specifications Grommet PLC: Programmable Logic Controller 2-wire load current is reduced (2.5 to 40 mA). Flexibility is 1.5 times greater than the conventional model (SMC comparison). Using flexible cable as standard spec.
Water Resistant 2-Color Indication Type Solid State Auto Switch: Direct Mounting Style D-M9NA(V)/D-M9PA(V)/D-M9BA(V) Auto Switch Specifications Grommet PLC: Programmable Logic Controller Water (coolant) resistant type 2-wire load current is reduced (2.5 to 40 mA). A proper operating range can be determined by the color of the light. (Red → Green ← Red) Using flexible cable as standard spec.
Reed Auto Switch Direct Mounting Style D-A90(V)/D-A93(V)/D-A96(V) For details about certified products conforming to international standards, visit us at www.smcworld.com.
Magnetic Field Resistant 2-Color Display Solid State Auto Switch D-P3DWSC/D-P3DWSE (Electrical entry: Pre-wired connector) For details about certified products conforming to international standards, visit us at www.smcworld.com. Auto Switch Specifications It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). A proper operating range can be determined by the color of the light.
Magnetic Field Resistant 2-Color Display Solid State Auto Switch D-P3DW/L/Z (Electrical entry: Grommet) For details about certified products conforming to international standards, visit us at www.smcworld.com. Auto Switch Specifications It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). A proper operating range can be determined by the color of the light.
ISO Standards [ISO/21287] Compact Cylinder (ATEX directive category 2) Series 55-C55 ø20,ø25,ø32,ø40,ø50,ø63,ø80,ø100 How to Order 55 C D 55 B 20 10 ATEX directive category 2 55 Rod end thread Nil M Compliant with ATEX directive category 2 Rod end female thread Rod end male thread Magnet Cylinder stroke (mm) None Built-in magnet Nil D Refer to page 2 for standard and intermediate strokes.
Safety Instructions Caution: These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ∗1), and other safety regulations. Caution indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury.