Datasheet

L
21
Symbol
Air Combination
Air Filter + Regulator
AC10B-A
AC10B M5
wq
• Option/Semi-standard: Select one each for a to g.
Option/Semi-standard symbol: When more than one specification is
required, indicate in alphanumeric order.
Example) AC10B-M5CG-T-12NR-A
How to Order
e
A
Refer to page 23 for size 20 to 60.
Symbol Description
q
Option
a Float type auto drain
Without auto drain
C
Note 1)
N.C. (Normally closed) Drain port is closed when pressure is not applied.
+
b Pressure gauge
Without pressure gauge
G
Note 2)
Round type pressure gauge (without limit indicator)
+
w
Attachment (T-spacer)
Note 3)
Without attachment
T Mounting position: AF+T+AR
+
e
Semi-standard
c Set pressure
Note 4)
0.05 to 0.7 MPa setting
1
0.02 to 0.2 MPa setting
+
d Bowl
Note 5)
Polycarbonate bowl
2
Metal bowl
6
Nylon bowl
+
e Exhaust mechanism
Relieving type
N
Non-relieving type
+
f Flow direction
Flow direction: Left to right
R
Flow direction: Right to left
+
g Pressure unit
Name plate, caution plate for bowl, and pressure gauge in imperial units: MPa
Z
Name plate, caution plate for bowl, and pressure gauge in imperial units: psi, °F
Note 1) When pressure is not applied, condensate which does not start the auto drain mechanism will be left in the bowl.
Releasing the residual condensate before ending operations for the day is recommended.
Note 2) A 1.0 MPa pressure gauge will be fi tted. It is not assembled and supplied loose at the time of shipment.
Note 3) The bracket position varies depending on the T-spacer mounting.
Note 4) Pressure can be set higher than the specifi cation pressure in some cases, but use pressure within the specifi cation range.
Note 5) Refer to Chemical data on page 46 for chemical resistance of the bowl.
21