Be sure to read before handling. Refer to front matters 42 and 43 for Safety Instructions
and pages 287 to 291 for F.R.L. Precautions.
Orange mark
Selection
1. Residual pressure disposal (outlet pressure removal) is not
possible for the AW20 to AW60 even though the inlet pressure
is exhausted. When the residual pressure disposal is per-
formed, use the filter regulator with backflow function (AW20K
to AW60K).
Warning
Maintenance
1. Replace the element every 2 years or when the pressure drop
becomes 0.1 MPa, whichever comes first, to prevent damage
to the element.
Warning
Mounting and Adjustment
1. Set the regulator while verifying the displayed values of the in-
let and outlet pressure gauges. Turning the regulator knob ex-
cessively can cause damage to the internal parts.
2. The pressure gauge included with regulators for 0.02 to 0.2
MPa setting is for up to 0.2 MPa use only (except the AW10).
Exceeding 0.2 MPa of pressure can damage the gauge.
3. Do not use tools on the pressure regulator knob as this may
cause damage. It must be operated manually.
1. Be sure to unlock the knob before adjusting the pressure and
lock it after setting the pressure. Failure to follow this proce-
dure can cause damage to the knob and the outlet pressure
may fluctuate.
Pull the pressure regulator knob to unlock. (You can visually
verify this with the “orange mark” that appears in the gap.)
Push the pressure regulator knob to lock. When the knob is
not easily locked, turn it left and right a little and then push it
(when the knob is locked, the “orange mark”, i.e., the gap will
disappear).
2. A knob cover is available to prevent careless operation of the
knob. Refer to page 389 for details.
Caution
Warning