SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
Cylinder port size
Push-in, Ø3.2 mm
Push-in, Ø4 mm
Push-in, Ø6 mm
M5 thread
Mixed sizes
or with port plug
Top-connected angle
with push-in, Ø3.2 mm
Top-connected angle
with push-in, Ø4 mm
Top-connected angle
with push-in, Ø6 mm
M5 thread
Bottom-connected angle
with push-in, Ø3.2 mm
Bottom-connected angle
with push-in, Ø4 mm
Bottom-connected angle
with push-in, Ø6 mm
M5 thread
Angle connector,
mixed sizes
When selecting CM/LM, enter size in
manifold specification sheet.
Number of valve stations
1 station
Maximum number of valve stations de-
pends on chosen electrical connection.
See Electrical connection/cable length.
Electrical connection/cable length
Input
D-side Connection/cable length
Valve
stations
2
F conn.
D-sub connector (25P) without cable
1 to 12
(24)
D-sub connector (25P) w. 1.5 m cable
D-sub connector (25P) w. 3 m cable
D-sub connector (25P) w. 5 m cable
P conn.
Flat cable (26P) without cable
1 to 12
(24)
Flat cable (26P) with 1.5 m cable
Flat cable (26P) with 3 m cable
Flat cable (26P) with 5 m cable
Flat cable (20P) without cable
1
1 to 9
(18)
T conn.
Terminal connection in box
1 to 10
(20)
L conn.
Cable (25 wire), 0.6 m wire length
1 to 12
(24)
Cable (25 wire), 1.5 m wire length
Cable (25 wire), 3 m wire length
M conn.
Multipole connector (26P) without cable
1 to 12
(24)
Multipole connector (26P) with 1.5 m cable
Multipole connector (26P) with 3 m cable
Multipole connector (26P) with 5 m cable
S connection
Distributed eldbus (EX500)
For eldbus without eldbus node
1 to 8
(16)
With eldbus node for Remote I/O
With eldbus node for DeviceNet/
PROFIBUS-DP/CC-LINK
Fieldbus with in- and outputs (EX250)
For eldbus without eldbus node
1 to 12
(24)
Fieldbus for DeviceNet
Fieldbus for PROFIBUS-DP
Fieldbus for CC-LINK
Fieldbus for CANopen
AS-i, 8 in/8 out, 31-slave model,
2 power supplies
1 to 4
(8)
AS-i, 4 in/4 out, 31-slave model,
2 power supplies
1 to 2
(4)
AS-i, 8 in/8 out, 31-slave model,
1 power supply
1 to 4
(8)
AS-i, 4 in/4 out, 31-slave model,
1 power supply
1 to 2
(4)
Fieldbus with outputs (EX126)
Fieldbus for CC-LINK
1 to 8
(16)
1. P connection: Order cables separately for type 20P.
2. Numbers in paranthesis indicates maximum number of solenoids for conguration
w. mixed single-double solenoid connections. Maximum number of valve stations is
determined by total number of solenoids. For mixed connections, use option symbol “K”.
Options
None
All stations with back-
pressure check valves
1
With DIN rail
(rail length: standard)
With DIN rail
(rail length: special)
2
Special wiring
(not double
wiring)
3
With name plate
External pilot
4
Direct exhaust with
built-in silencer
5
Specify options in alphabetical order.
Example: BRS.
1. When using backpressure check
valves only on neccessary stations, en-
ter check valve part number and valve
station number in manifold specifica-
tion sheet.
2. For special DIN rail length, enter
D. ( = number of valve stations.)
Example: D08. In this case, manifold
is mounted on DIN rail for 8 stations,
regardless of actual number of stations
in manifold. Entered number of stations
must be larger than actual number of
stations in manifold. Enter D0 for op-
tions without DIN rail.
3. Ensure that wiring is entered in
manifold specification sheet.
4. For external pilot option “R”,
also enter external pilot option “R” for
valves in question.
5. Option with built-in silencer does
not meet requirement of IP67.
Input block (only entered when
input blocks are used)
Without eldbus node/
input block (SD0)
Without input block
With 1 input block
With 8 input blocks
Type of input block (only
entered when input blocks are used)
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs (3 pins)
Polarity, input block
(only entered when input blocks
are used)
PNP (+) or without
eldbus node/
input block
Fieldbus polarity
Polarity
Leave box for fieldbus polarity blank for manifold without bus node (SD0).
Part number: valve manifold – for VQC1000 plate assembly/plug-in unit
connection
connection
Series VQC1000
Plate assembly/plug-in