Datasheet

2
35
VBA10A VBA11A VBA20A VBA40A VBA43A
G1/4 G3/8 G1/2
0.1–1 MPa (1–10 bar)
0.2–2 MPa (2–20 bar) 0.2–1 MPa (2–10 bar)
0.2–1.6 MPa
(2–16 bar)
2:1 4:1
400 l
n
/min 100 l
n
/min 1000 l
n
/min 1900 l
n
/min 2300 l
n
/min
VBA10A-F02GN G1/4
VBA11A-F02GN G1/4
VBA20A-F03GN G3/8
VBA40A-F04GN G1/2
VBA43A-F04GS G1/2
VBAT05AF-SV-Q 5 l
2 MPa (20 bar)
VBAT10AF-SV-Q 10 l
VBAT20AF-RV-Q 20 l
1 MPa (10 bar)
VBAT38AF-RV-Q 38 l
KT-VBA10A-1 VBA10A
KT-VBA11A-20 VBA11A
KT-VBA20A-1 VBA20A
KT-VBA40A-1 VBA40A
KT-VBA43A-1 VBA43A
G27-20-01 VBA10A, VBA11A, VBA43A
G36-10-01 VBA20A, VBA40A
Subject to changes
AIR PREPARATION EQUIPMENT
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VBA pressure booster
Modell
Medium Compressed air, not lubricated
1
Degree of ltration Microlter 0.03 µm (SMC’s AM or AFM series)
Connection
Inlet pressure
Secondary pressure
Max. pressure boost
Flow 1:1
1. If components after the pressure booster require lubrication, lubricate after pressure booster.
Raises main line pressure to the preset value Requires no wiring
Ability to reduce the main line pressure
Pressure booster including pressure gauge
Part number Connection
Pressure tank designed for booster VBA
Part number Volume Pressure
Pressure booster ordered separately.
Service set
Part number Fits
Pressure gauge spare part
Part number Fits
Function
Pressure booster VBA raises main line pressure to an
adjustable value. A built-in pressure regulator ensures
constant output pressure. The time for lling a tank with
increased pressure can be reduced by parallel operation
with non-return valve. Pressure booster is only activated
when tank pressure does not corresponds to main line
pressure.
Pilot operated and ATEX versions available on request.
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE