Datasheet

4
158
2.4 MPa (24 bar)
2 SGC200
3 SGC300
4 SGC400
S
Z
D
DO
W
B1 B2
D
05 0–0.5 MPa
10 0–1 MPa
16 0–1.6 MPa
L
Z
Rc
G G (ISO1179)
N NPT
T NPTF
S
M
A
B
C
D
10 3/8"
SGC200
15 1/2"
20 3/4" SGC300
25 1" SGC400
3
110 VAC [115 VAC]
50/60 Hz
4
220 VAC [230 VAC]
50/60 Hz
5 24 VDC
6 12 VDC
1
2
A NBR
B FKM
SGC
SGCA
-
-
10
10
2
2
A
A
1
1
3 D05
05
Z A
A
-
-
-
-
-2
2
Y
0.5 MPa
SGC(A)22-0510
3/8" 15 mm 5.4 4.6 0.69 (0.74) 0.73 (0.78)
SGC(A)22-0515
1/2" 15 mm 7.6 6.5 0.69 (0.74) 0.73 (0.78)
SGC(A)32-0520
3/4" 20 mm 13.8 11.8 1.04 (1.11) 1.08 (1.15)
SGC(A)42-0525
1" 25 mm 21.4 18.3 1.7 (1.77) 1.74 (1.81)
1 MPa
SGC(A)22-1010
3/8" 12 mm 4.1 3.5 0.69 (0.74) 0.73 (0.78)
SGC(A)22-1015
1/2" 12 mm 5.6 4.8 0.69 (0.74) 0.73 (0.78)
SGC(A)32-1020
3/4" 14 mm 8.3 7.1 1.04 (1.11) 1.08 (1.15)
SGC(A)42-1025
1" 17 mm 12.9 11.0 1.7 (1.77) 1.74 (1.81)
1.6 MPa
SGC(A)22-1610
3/8" 9 mm 1.5 1.25 0.69 (0.74) 0.73 (0.78)
SGC(A)22-1615
1/2" 9 mm 3.2 2.7 0.69 (0.74) 0.73 (0.78)
SGC(A)32-1620
3/4" 12 mm 5.3 4.5 1.04 (1.11) 1.08 (1.15)
SGC(A)42-1625
1" 15 mm 8.6 7.3 1.7 (1.77) 1.74 (1.81)
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
SGC 2/2 air operated valve for cutting uids
Medium Cutting uids
Degree of ltration Use SMC’s industrial lters FG, FGF, FN or equivalent
Provtryck
Max. differential pressure (port 1 to 2) 0.5 MPa (5 bar), 1.0 MPa (10 bar) or 1.6 MPa (16 bar)
Operating temperature –5 to +60 °C (no freezing)
Ambient temperature –5 to +50 °C (no freezing)
Pilot pressure
0.5 MPa-type: 0.25 MPa (2.5 bar) to 0.7 MPa (7 bar);
1.0 and 1.6 MPa-type: 0.3 MPa (3 bar) to 0.7 MPa (7 bar)
Voltage
Valve with pilot valve tted, standard: 24 VDC or 230 VAC.
Other voltages on request.
Flow factor (Cv) See table
Enclosure
Valve with pilot valve tted: IP65
(with DIN43650B connector)
Part number:
Contact SMC for more information.
Series
LED/surge voltage suppressor
None
With surge voltage suppressor
With LED and surge
voltage suppressor
Electrical connection
With DIN connector
For DIN connector (connec-
tor ordered separately)
With M12 connector
1
1. Cable ordered separately.
Mounting bracket/mounting position
Without mounting bracket Bracket to the left Bracket to the right
Manual override
Non-lockable
push type
Locking push and
turn type
Pressure range
Cable length
0.5 meters
3 meters
5 meters
Thread type
No. of position sensors
2 pcs.
1 pc.
Valve position sensor
1
Without position sensors
(without magnet)
Without position sensors
(with magnet)
D-M9N, 3-wire (NPN)
D-M9P, 3-wire (PNP)
D-M9B, 2-wire
D-F9BA, 2-wire
1. See end of chapter 6 for detailed
information about sensors.
Port size
Rated voltage
Valve type
Normally closed (NC)
Normally open (NO)
Seal material
Pilot valve tted
Air operated
With pilot valve tted
Technical data
Pressure
range Model
Port
size
Orice
diameter
Kv
factor
Cv
factor
Weight in kg
1
Air
operated
Pilot valve
tted
1. Weight in paranthesis includes mounting bracket.
L
IN
R L
IN
R
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE