Datasheet
4
127
■
10 µm
VP342: 1000 l
n
/min; VP542: 2200 l
n
/min;
VP742: 3600 l
n
/min
➊
3 VP300
5 VP500
7 VP700
➋
R
➎
DC
5 24 VDC
6 12 VDC
AC (50/60 Hz)
1 100 VAC
2 200 VAC
3 110 VAC [115 VAC]
4 220 VAC [230 VAC]
7 240 VAC
➌
K
➍
T
➏
G
L
M
Y
H
LN MN
G
YO
H
LO MO
DC
AC — — —
➓
Rc
F G
N NPT
T NPTF
⓬
F
⓫
A
B
⓭
—
X500
➑
D E
➒
VP300
VP500
VP700
01 1/8
✔
— —
02 1/4
✔ ✔
—
03 3/8 —
✔ ✔
04 1/2 — —
✔
VP - 53 42 1-G 01 A - -
➊ ➋ ➌ ➍ ➎ ➏ ➐ ➑ ➒ ➓
⓫ ⓬ ⓭
➐
DC AC
✔ ✔
S
✔
—
1
Z
✔ ✔
R
✔
—
U
✔
—
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VP – 3/2 solenoid valve, body ported
Medium Air, lubricated or not lubricated
Degree of ltration
Max. working pressure 0.7 MPa (7 bar); high pressure 1 MPa (10 bar)
Min. working pressure 0.2 MPa (2 bar); external pilot –100 kPa
Operating temperature –10 to 50 °C
Ambient temperature –10 to 50 °C
Voltage/power 24 VDC/1.5 W; for others, see part number
Flow
Enclosure IP40; DIN connector: IP65
Manual override Standard: lockable; see part number
Choose VG342 for larger flow.
■ Robust design ■ Large ow rates ■ Easy to change NC or NO
See VPA for air operated version.
Series
Pilot type
Internal pilot
External pilot
Rated voltage
Pressure specication
Standard (0.7 MPa)
High pressure
(1.0 MPa)
Solenoid specication
Standard
With energy saving cir-
cuit, 0.55 W (DC only)
Choose energy saving type if valve will
be energized for a long time.
T-type can be chosen for DC only.
If T-type is chosen, the only LED/surge
voltage suppressor available is type Z.
(When DIN type electrical connection w/o
connector is used, only YOS can be chosen.)
Part number: solenoid valve
Electrical connection
Single wire L connector M connector
DIN connector
(EN175301-803)
Wire length
300 mm
With wire
(300 mm)
With wire
(300 mm)
IP65 enclosure
With connector
Wire length
600 mm
Without wire Without wire
Without LED/ surge
voltage suppressor
Wire length
300 mm
W/o connector
Wire length
600 mm
W/o connector W/o connector
Thread type
Mounting bracket
Without bracket
With bracket
Valve function
NC (normally closed)
NO (normally open)
Made to order
Pilot exhaust port with
thread (M3)
Manual override
Non-lockable push type Push-turn for screwdriver Push-turn with arm
Port size
Size
Only DIN connector type available
for AC voltage. See “electrical con-
nection” for detailed specifications.
LED/surge voltage suppressor
Without LED and surge voltage suppressor
With surge voltage suppressor
With LED and surge voltage suppressor
With surge voltage suppressor (bipolar)
W/o LED and surge voltage suppressor (bipolar)
1. S-version is not available for AC type, since rectifier protects against surges.
For DIN connector: Since connector comes with LEDs, versions YOZ or YOU are
not available.
Contact SMC for more information.
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE