Datasheet

4
153
1.5 MPa (15 bar)
0.02 MPa (0.2 bar)
VXED VXD
VXD2130 1.8 W 5.5 W
19 VAC 9 VAC
VXD2140/2150 1.5 W 4.5 W
VXD2260 2.3 W 7 W 43 VAC 19 VAC
VXED2130-02F-5D1 0.7 MPa G1/4 1.9/1.6 10 mm 0.45 kg
VXED2130-03F-5D1 0.7 MPa G3/8 2.4/2.1 10 mm 0.45 kg
VXED2130-04F-5D1 0.7 MPa G1/2 2.4/2.1 10 mm 0.53 kg
VXED2140-03F-5D1 1 MPa G3/8 4.5/3.9 15 mm 0.7 kg
VXED2140-04F-5D1 1 MPa G1/2 5.5/4.7 15 mm 0.7 kg
VXED2150-06F-5D1 1 MPa G3/4 9.5/8.1 20 mm 1.18 kg
VXED2260-10F-5D1 1 MPa G1 13/11.1 25 mm 1.68 kg
VXD2130-02F-JDR1 0.9 MPa G1/4 1.9/1.6 10 mm 0.45 kg
VXD2130-03F-JDR1 0.9 MPa G3/8 2.4/2.1 10 mm 0.45 kg
VXD2130-04F-JDR1 0.9 MPa G1/2 2.4/2.1 10 mm 0.53 kg
VXD2140-03F-JDR1 1 MPa G3/8 4.5/3.9 15 mm 0.7 kg
VXD2140-04F-JDR1 1 MPa G1/2 5.5/4.7 15 mm 0.7 kg
VXD2150-06F-JDR1 1 MPa G3/4 9.5/8.1 20 mm 1.18 kg
VXD2260-10F-JDR1 1 MPa G1 13/11.1 25 mm 1.68 kg
VXD2142-03F-5D1 0.7 MPa G3/8 4.5/3.9 15 mm 0.72 kg
VXD2142-04F-5D1 0.7 MPa G1/2 5.5/4.7 15 mm 0.72 kg
VXD2152-06F-5D1 0.7 MPa G3/4 9.5/8.1 20 mm 1.2 kg
VXD2262-10F-5D1 0.7 MPa G1 13/11.1 25 mm 1.72 kg
VXD2142-03F-JDR1 0.7 MPa G3/8 4.5/3.9 15 mm 0.72 kg
VXD2142-04F-JDR1 0.7 MPa G1/2 5.5/4.7 15 mm 0.72 kg
VXD2152-06F-JDR1 0.7 MPa G3/4 9.5/8.1 20 mm 1.2 kg
VXD2262-10F-JDR1 0.7 MPa G1 13/11.1 25 mm 1.72 kg
Subject to change
SOLENOID VALVES, MECHANICAL AND MANUAL VALVES
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +31 (0) 20 531 88 88 / INFO@SMCPNEUMATICS.NL
VXD21 & -22 pilot operated solenoid valve
for water & other neutral media
Medium Clean water and neutral media
1
Degree of ltration Suitable lter: 80–100 mesh
Max. static pressure
Min. differential pressure
Max. differential pressure
VXD2130: 0.7 MPa (7 bar)
Others:1.0 MPa (10 bar)
Medium temperature 1 to 60 °C
Ambient temperature –10 to 60 °C
Voltage
Standard: 24 VDC, or 230 VAC,
other voltages on request
Power consumption See table below
Flow factor (Cv/Kv) See table below
Enclosure IP65 (with DIN43650A connector)
Manual override Not available
LED, surge voltage suppressor Options
1. Contact SMC for advice for other media than water, other pressures, voltages, temperatures or body materials.
Valve series
Power consumption DC Power consumption AC
Onset Holding
Valve
24 VDC, normally closed, energy saving version
Part number
Max. diff.
pressure Connection
Cv/Kv
factor Orice Weight
230 VAC, normally closed
Part number
Max. diff.
pressure Connection
Cv/Kv
factor Orice Weight
24 VDC, normally open
Part number
Max. diff.
pressure Connection
Cv/Kv
factor Orice Weight
230 VAC, normally open
Part number
Max. diff.
pressure Connection
Cv/Kv
factor Orice Weight
Energy saving version, series VXED, is now standard for 24 VDC, NC. Contact SMC for more information.
Power consumption reduced by 2⁄3 Easy to order: VXD is replaced with VXED
Reduced operating costs Longer life Reduced environmental impact Meets RoHS requirements
= DELIVERY EX-STOCK FOR MORE INFO, ASK THE SMC EXPERTS: PHONE +32 (0) 3 355 1464 / INFO@SMCPNEUMATICS.BE