6. ATTACHMENTS / ACCESSORIES OPTIONS PART NUMBER
Spacer
Spacer with bracket
Pressure switch
Note6)
Note1)
in part numbers for a round pressure gauge indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
Please contact SMC regarding the pipe thread type NPT and the supply of pressure gauge with psi unit display specifications.
Note2) Including one O-ring and 2 mounting screws
Note3) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting screw (2 pcs.) are attached. [ ]: Switch body only.
Regarding how to order the digital pressure switch, refer to the WEB catalog or the Best Pneumatics No.6.
Note4) Minimum operating pressure: N.O. type–0.1 MPa (AD38-A, AD48-A); N.C. type–0.1 MPa (AD17-A, AD27-A) and 0.15 MPa (AD37-A, AD47-A).
of float type auto drain product number shows the type of the outside diameter of the application tube. Indicate Nil for φ 10 and N for φ 3/8".
Please consult with SMC separately for psi and °F unit display specifications.
Note5) For F.R.L. units, port sizes without ( ) are standard specifications.
Note6) Separate spacers are required for modular unit.
in part numbers for each attachment indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
7. TROUBLE SHOOTING
○ Air combination Connected part
1. Breakage of packing.
2. Retainer connection nut is loose.
 
For individual product troubleshooting, refer to the operation manual of each product.
8. SPARE PARTS LIST
Air combination AC junction
Note1)
Refer to "10DISASSEMBLY DRAWING" on page 21 to 22 for Packing.
Note2) Assembly of 2 O-rings
For spare parts of each product, refer to the operation manual and catalog.
19
Pressure switch with
Note6)
piping adapter
Possible cause
Section
Leak
AC55*-B
Y520P-050S
Y620P-050S
AC25*-B
AC30*-B
AC40*-B
AC40*-06-B
AC60*-B
Phenomenon
Packing
Note 1
Y120P-050AS
Note 2
Y220P-050S
Y320P-050S
Y420P-050S
AC50*-B
AC10*-A
AC20*-B
Description
Spare parts part number
Y54-03-A
(See "Assembly" of "9HOW TO REPLACE" on page 20.)
Remedy
1. Replace the packing.
2. Tighten connection nut to the specified torque.
Air leakage from
connected part
Trouble
Y24-02-A
Y34-02-A
Y44-03-A
Y54-04-A
Cross spacer
Note6)
Y14-M5-A
Y24-01-A
Y34-01-A
Y44-02-A
IS10E-4004-A
IS10E-2003-A
IS10E-3004-A
IS10E-4006-A
IS10E-2002-A
IS10E-3003-A
E400-06-A
IS10E-4002-A
IS10E-2001-A
IS10E-3002-A
IS10E-4003-A
E600-06-A
Piping adapter
Note6)
E100-M5-A
E200-02-A
E300-03-A
E500-06-A
E400-04-A
E600-10-A
E200-03-A
E300-04-A
E400-02-A
E200-01-A
E300-02-A
E400-03-A
Pressure relief 3 port valve
Note6)
VHS40-03A
VHS40-06A
VHS20-02A
VHS30-03A
VHS40-04A
VHS40-02A
VHS20-01A
VHS30-02A
VHS50-06A
VHS50-10A
Y610-03-A
Y610-(03)-A
Y210-(02)-A
Y310-02-A
Y410-03-A
Y510-03-A
Y610-(04)-A
Y610-04-A
T-Spacer
Note5) Note6)
Y110-M5-A
Y210-01-A
Y310-(01)-A
Y410-(02)-A
Y510-(02)-A
IS10M-20-A
IS10M-30-A
IS10M-40-A
IS10M-50-A
IS10M-60-A
AKM2000-(02)-A
AKM3000-02-A
AKM4000-03-A
Y200T-A
Y300T-A
Y400T-A
Y500T-A
Y600T-A
Check valve
Note5) Note6)
AKM2000-01-A
AKM3000-(01)-A
AKM4000-(02)-A
AD38-A
AD48-A
Attachment
Y100-A
Y200-A
Y300-A
Y400-A
Y500-A
Y600-A
Y100T-A
ISE35-R-65-MLAISE35-R-65-M (Switch body only)]
Note 3
Float type
Note4)
auto drain
N.C.
AD17-A
AD27-A
AD37-A
AD47-A
N.O.
GC3-4AS [GC3P-010AS (Pressure gauge cover only)]
NPN output
Wiring bottom entry
ISE35-N-25-MLAISE35-N-25-M (Switch body only)]
Note 3
NPN output
Wiring top entry
ISE35-R-25-MLAISE35-R-25-M (Switch body only)]
Note 3
PNP output
Wiring bottom entry
ISE35-N-65-MLAISE35-N-65-M (Switch body only)]
Note 3
PNP output
Wiring top entry
(with color zone)
0.2 MPa setting
G36-4-01-L
G46-4-01-L
Square
Note2)
embedded type
Standard
GC3-10AS [GC3P-010AS (Pressure gauge cover only)]
0.2 MPa setting
G27-10-R1
G36-4-01
G46-4-01
Round type
Standard
G36-10-01-L
G46-10-01-L
For AC55*-B
For AC60*-B
Option
Pressure gauge
Round type
Standard
G27-10-R1
G36-10-01
G46-10-01
0.2 MPa setting
Digital pressure
switch
Section
Attachments / Accessories (Options) part number
For AC10*-A
For AC20*-B
For AC25*-B
For AC30*-B
For AC40*-B
For AC40*-06-B
For AC50*-B
Note1)
Descriptio
Model