6. ATTACHMENTS / ACCESSORIES (OPTIONS) PART NUMBER
Spacer
Spacer with bracket
Pressure switch
Note6)
Note1)
□ in part numbers for a round pressure gauge indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
Please contact SMC regarding the pipe thread type NPT and the supply of pressure gauge with psi unit display specifications.
Note2) Including one O-ring and 2 mounting screws
Note3) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting screw (2 pcs.) are attached. [ ]: Switch body only.
Regarding how to order the digital pressure switch, refer to the WEB catalog or the Best Pneumatics No.6.
Note4) Minimum operating pressure: N.O. type–0.1 MPa (AD38-A, AD48-A); N.C. type–0.1 MPa (AD17-A, AD27-A) and 0.15 MPa (AD37-A, AD47-A).
□ of float type auto drain product number shows the type of the outside diameter of the application tube. Indicate Nil for φ 10 and N for φ 3/8".
Please consult with SMC separately for psi and °F unit display specifications.
Note5) For F.R.L. units, port sizes without ( ) are standard specifications.
Note6) Separate spacers are required for modular unit.
□ in part numbers for each attachment indicates a pipe thread type. No indication is necessary for R; however, indicate N for NPT.
7. TROUBLE SHOOTING
○ Air combination (Connected part)
1. Breakage of packing.
2. Retainer connection nut is loose.
○For individual product troubleshooting, refer to the operation manual of each product.
8. SPARE PARTS LIST
○ Air combination (AC junction)
Note1)
Refer to "10.DISASSEMBLY DRAWING" on page 21 to 22 for ①Packing.
Note2) Assembly of 2 O-rings
○For spare parts of each product, refer to the operation manual and catalog.
19
Pressure switch with
Note6)
piping adapter
Possible cause
Section
Leak
AC55*-B
Y520P-050S
Y620P-050S
AC25*-B
AC30*-B
AC40*-B
AC40*-06-B
AC60*-B
Phenomenon
①Packing
Note 1)
Y120P-050AS
Note 2)
Y220P-050S
Y320P-050S
Y420P-050S
AC50*-B
AC10*-A
AC20*-B
Description
Spare parts part number
-
-
Y54-□03-A
(See "Assembly" of "9.HOW TO REPLACE" on page 20.)
Remedy
1. Replace the packing.
2. Tighten connection nut to the specified torque.
Air leakage from
connected part
Trouble
-
Y24-□02-A
Y34-□02-A
Y44-□03-A
Y54-□04-A
Cross spacer
Note6)
Y14-M5-A
Y24-□01-A
Y34-□01-A
Y44-□02-A
-
-
IS10E-40□04-A
IS10E-20□03-A
IS10E-30□04-A
IS10E-40□06-A
-
IS10E-20□02-A
IS10E-30□03-A
-
-
E400-□06-A
IS10E-40□02-A
IS10E-20□01-A
IS10E-30□02-A
IS10E-40□03-A
E600-□06-A
Piping adapter
Note6)
E100-M5-A
E200-□02-A
E300-□03-A
E500-□06-A
E400-□04-A
E600-□10-A
E200-□03-A
E300-□04-A
E400-□02-A
E200-□01-A
E300-□02-A
E400-□03-A
Pressure relief 3 port valve
Note6)
-
VHS40-□03A
VHS40-□06A
VHS20-□02A
VHS30-□03A
VHS40-□04A
VHS40-□02A
-
-
VHS20-□01A
VHS30-□02A
VHS50-□06A
VHS50-□10A
Y610-□03-A
Y610-(□03)-A
Y210-(□02)-A
Y310-□02-A
Y410-□03-A
Y510-□03-A
Y610-(□04)-A
Y610-□04-A
T-Spacer
Note5) Note6)
Y110-M5-A
Y210-□01-A
Y310-(□01)-A
Y410-(□02)-A
Y510-(□02)-A
-
IS10M-20-A
IS10M-30-A
IS10M-40-A
IS10M-50-A
IS10M-60-A
-
-
-
-
AKM2000-(□02)-A
AKM3000-□02-A
AKM4000-□03-A
Y200T-A
Y300T-A
Y400T-A
Y500T-A
Y600T-A
Check valve
Note5) Note6)
-
AKM2000-□01-A
AKM3000-(□01)-A
AKM4000-(□02)-A
AD38□-A
AD48□-A
Attachment
Y100-A
Y200-A
Y300-A
Y400-A
Y500-A
Y600-A
Y100T-A
ISE35-R-65-MLA[ISE35-R-65-M (Switch body only)]
Note 3)
Float type
Note4)
auto drain
N.C.
AD17-A
AD27-A
AD37□-A
AD47□-A
N.O.
-
-
-
GC3-4AS [GC3P-010AS (Pressure gauge cover only)]
NPN output
Wiring bottom entry
-
ISE35-N-25-MLA[ISE35-N-25-M (Switch body only)]
Note 3)
NPN output
Wiring top entry
ISE35-R-25-MLA[ISE35-R-25-M (Switch body only)]
Note 3)
PNP output
Wiring bottom entry
ISE35-N-65-MLA[ISE35-N-65-M (Switch body only)]
Note 3)
PNP output
Wiring top entry
(with color zone)
0.2 MPa setting
-
G36-4-□01-L
G46-4-□01-L
Square
Note2)
embedded type
Standard
-
GC3-10AS [GC3P-010AS (Pressure gauge cover only)]
0.2 MPa setting
G27-10-R1
G36-4-□01
G46-4-□01
Round type
Standard
-
G36-10-□01-L
G46-10-□01-L
For AC55*-B
For AC60*-B
Option
Pressure gauge
Round type
Standard
G27-10-R1
G36-10-□01
G46-10-□01
0.2 MPa setting
Digital pressure
switch
Section
Attachments / Accessories (Options) part number
For AC10*-A
For AC20*-B
For AC25*-B
For AC30*-B
For AC40*-B
For AC40*-06-B
For AC50*-B
Note1)
Descriptio
Model