Datasheet

Symbol Description
q
Body size
20 25 30 40 50 60
y
Semi-standard
c
Set
pressure
Note 6)
0.05 to 0.85 MPa setting
1
0.02 to 0.2 MPa setting
+
d
Exhaust
mechanism
Relieving type
N
Non-relieving type
+
e Flow direction
Flow direction: Left to right
R
Flow direction: Right to left
+
f Knob
Downward
Y
Upward
+
g Pressure unit
Name plate and pressure gauge in imperial units: MPa
Z
Note 7)
Name plate and pressure gauge in imperial units: psi
Note 9) Note 9) Note 9) Note 9) Note 9) Note 9)
ZA
Note 8)
Digital pressure switch: With unit conversion function
Note 10) Note 10) Note 10) Note 10) Note 10) Note 10)
Model
AR20-B AR25-B AR30-B AR40-B AR40-06-B AR50-B AR60-B
Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8
1/4, 3/8, 1/2
3/4 3/4, 1 1
Pressure gauge port size
Note 1)
1/8
Fluid Air
Ambient and fl uid temperature
Note 2)
–5 to 60°C (with no freezing)
Proof pressure 1.5 MPa
Maximum operating pressure 1.0 MPa
Set pressure range 0.05 to 0.85 MPa
Construction Relieving type
Weight [kg] 0.16 0.21 0.29 0.44 0.47 1.17 1.22
Note 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch.
Note 2) –5 to 50°C for the products with the digital pressure switch
Standard Specifi cations
Note 1) Set the inlet pressure to at least 0.05 MPa higher than the set pressure.
Note 2) Option B, G, H, M are not assembled and supplied loose at the time of
shipment.
Note 3) Assembly of a bracket and set nuts (applicable to the AR20(K)-B to
AR40(K)-B). Including 2 mounting screws for the AR50(K)-B and AR60(K)-B
Note 4) When the pressure gauge is attached, a 1.0 MPa pressure gauge will be fi tted
for standard (0.85 MPa) type. 0.4 MPa pressure gauge for 0.2 MPa type.
Note 5) When choosing with H (panel mount), the installation space for lead wires will
not be secured. In this case, select “wiring top entry” for the electrical entry.
(Select “wiring bottom entry” when the semi-standard Y is chosen
simultaneously.)
Note 6) Pressure can be set higher than the specifi cation pressure in some cases, but
use pressure within the specifi cation range.
Note 7) For pipe thread type: NPT.
Cannot be used with M: Round pressure gauge (with colour zone). Available
by request for special.
The digital pressure switch will be equipped with the unit conversion function,
setting to psi initially.
Note 8) For options: E1, E2, E3, E4.
Note 9) : For pipe thread type: NPT only
Note 10) : Select with options: E1, E2, E3, E4.
AR40-B, AR40K-BAR20-B, AR20K-B
66
Regulator
Series AR20-B to AR60-B
Regulator with Backfl ow Function
Series AR20K-B to AR60K-B
AC
AF
AR
ALAW
ALAF
ARAF
AFM
ARAW
AFM
AF Attachment
AFM / AFD
ARALAW