User Manual

14
Traceability control system PC software
to move to next operation.
Auto: After the tightening times have reached the set number, next operation will begin
automatically.
(5) [Wrench operation lock] (Only for HTW)
Invalid: The settings can be changed on the torque wrench.
(* There are restrictions. For details, see VII. Wrench operation.)
Valid: The settings cannot be changed on the torque wrench.
(6) [Date setting]
Invalid: The time and date information of the set torque wrench is maintained.
Valid: The data on the torque wrench are overwritten by the current time and date information
on the PC.
Torque data can be managed on date information.
(7) [Sleep timer (min)] (Only for HTW)
When no operation has been performed on the torque wrench for the set period of time, the
torque wrench will switch to sleep mode (power saving mode) automatically.
Lift the torque wrench to restart. No button operation is required.
(8) [Auto off timer (hrs.)]
When the set period of time has elapsed in sleep mode, power will be turned off automatically.
If Sleep timer is turned OFF, when no operation has been performed for the Auto off set time,
power will be turned off automatically.
(9) [Advance alarm 1] / [Advance alarm 5]
When the tightening torque value has reached the set percentage of Lower torque, a warning
will be given with the buzzer and vibration. Five alarm settings are available.
Please set from No. 1 in the order the advance alarm.
6-2) Operating
1) Reading torque wrench setting data
[Menu bar Communication Reading] [Reading]icon
Reads out torque data stored in the memory of the torque wrench.
2) Writing the settings
[Menu bar Communication Data writing] [Data writing]icon
Writes in the settings made on the PC to the torque wrench.
Setting writing warning
Point
If there are data remaining in the torque wrench body, you cannot change the
setting .In advance, please delete the data.