User's Manual
1 Parking Column
1.2 Parking Column for System SPT 400
Page 4 © SKIDATA AG, Version 1.0
Ensure the following before proceeding with the installation:
The concrete foundation must be exactly horizontal. Installing
the device on an uneven surface may cause the chassis to
become warped or damaged. If levelling of the surface is not
possible, the parking column must be level-adjusted, e.g. by
using additional hexagon nuts (see Fig. Hexagon nuts as
spacers); in that case the threaded rods must be allowed to
protrude further.
The surface of the concrete foundation must be even and ex-
actly horizontal
Cable protection tubes should be cut approx. 2 cm above the
concrete surface
1.2.1 Installation
The threaded rods should protrude approx. 50 mm from the
concrete surface
The fastening tension of the hexagon nuts must not exceed
20 Nm
Use washers with large outer diameter (∅ = 30 mm, as per
UN 737 standard)
The parking column must be aligned exactly horizontally