MorningStar Integration Guide

REV
20201125
SimpliPhi Power, Inc. | 3100 Camino Del Sol | Oxnard, CA 93030, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 7 |
4.2 Charge Controller Settings
Please review Table 2.0 below for Morningstar charge controller(s) program settings.
Table 2.0 - Settings for SimpliPhi PHI 730, 1.4, 2.9 & 3.8 kWh Batteries w/ Morningstar Charge Controller
CHARGE CONTROLLER
PHI 730, 1.4, 2.9 & 3.8 kWh; 24V / 48V
Setting
Charging Source
Source
12 / 24 / 48
Battery Voltage (V) Custom
Charge
Battery Charge Setpoints
Volts
EQ (V)
Off
Absorb (V)
14 / 28 / 56
Float (V)
13.5 / 27 / 54
ChgTime
Absorb Minimum (Mins)
6 Min / .1 Hour
EQ Time (Mins)
0
EQ Time (Days) 0
Float Timeout Please See Note
Limits
Output Amps
1,2
28.5A per PHI730 12V; 14A per PHI730 24V
40A per PHI1.4 12V; 28.5A per PHI1.4 24V
75A per PHI3.8 24V; 37.5A per PHI3.8 48V
Input Amps
1
Size based on input charging source
Notes:
1.
Per PHI battery Refer to Section 3.0 herein for charge controller PHI battery bank sizing.
2.
Per PHI battery These settings are calculated by multiplying the nominal value per each PHI battery times the # of
PHI batteries. For other batteries, refer to the Warranty and Specification Sheet for the specific model.
3.
Float Timeout setting can be used in place of a ReBulk setting. Adjust this setting to the desired time you would like
the battery to remain below the float voltage before entering into a its bulk stage charging cycle. Levels are typical @
25°C and may need adjusting at temperature extremes.
When performing rapid deep charge/discharge cycles, the PHI battery should be allowed to "rest" 15 minutes in
between.
Always refer to the SimpliPhi Power Manual and Warranty for the specific PHI battery model.
CAUTION: When PHI battery quantities change, the capacity & charge/discharge current
settings must be reassessed. Failure to do so will void the Warranty.