User Manual

SGD-SB2025NT-TM, Part 2
Jan 12 Page 106
APPENDIX A
Topic Description Options/Notes Type Location (ET page) ET
Channel
Facilities
TX Key Hang 0 secs – 5 secs Select
Channel Setup (Setup
button, channel tab)
TM ET
Channel
Facilities
TM Triggered T/T
None/Perm/Central NI
fail
Select
Channel Setup (Setup
button, channel tab)
TM ET
CTCSS CTCSS frequency
50 Hz to 300 Hz (to
0.1 Hz)
Enter
Channel Setup (Setup
button, channel tab)
TM ET
CTCSS CTCSS out route Feature not in use Button
NI Engineering
(CTCSS tab)
Both ET
CTCSS
CTCSS tone O/P –
fine level
Approx 3 dB range Slider
NI Engineering
(CTCSS tab)
Both ET
CTCSS
CTCSS tone O/P –
coarse level
0 dB to −21 dB (3 dB
steps)
Slider
NI Engineering
(CTCSS tab)
Both ET
DSP Firmware
Read in FW file Load file into ET Button DSP button (Loader) NI ET
DSP Firmware
Upload FW to NI Start upload process Button DSP button (Loader) NI ET
Environment Set I/O text tables Max 20 characters Enter Setup (Labels tab) Either
Environment
Configure the
environment I/Ps
Monitor/Auto with
invert options
Select Setup (Misc tab) Either
Environment
Configure the
environment O/Ps
Manual/Auto Select Setup (Misc tab) Either
Environment
Environment O/P
control
O/Ps 1 to 8: On/Off Button
NI Engineering
(Facilities tab)
Either
GPS View GPS signals No action GPS (GPS button) Either
GPS Set PC Clock Select
GPS > Options menu
(GPS button)
Either
Isolated I/Ps
Configure isolated
I/Ps
Monitor/Auto Select Setup (Misc tab) Both ET
Isolated O/Ps
Configure isolated
O/Ps (relays)
Manual/Auto Select Setup (Misc tab) Both ET
NI Facilities
Inhibit controls: I/P
and/or O/P
On/Off Button
NI Engineering
(Facilities tab)
Both ET
NI Facilities
Isolated (relay) O/P
controls
Relay 1 to 3: On/Off Button
NI Engineering
(Facilities tab)
Both ET
NI Facilities Line fail T/T On/Off Button
NI Engineering
(Station tab)
Both ET
NI Name
Set Station/Central NI
name
Max 20 characters Enter Setup (Labels tab) Both ET
NI Network Set IP address
Set to suit network
addressing scheme
Enter
NI Setup (Network
button)
NI ET
NI Network Set Subnet mask Feature not in use Enter
NI Setup (Network
button)
NI ET
NI Network Set default gateway Feature not in use N/A
NI Setup (Network
button)
NI ET
NI Network Enable NI Enable/Disable Check
NI Setup (Network
button)
NI ET
Signalling In I/P signal type Tone/Voltage Select Setup (Signalling tab) Both ET
Signalling In
Boundaries: min &
max
Tone: 2.6 – 3.5 kHz
V’age: 1 – 1023
Enter Setup (Signalling tab) Both ET
Signalling Out
O/P tone frequency 2.5 kHz – 3.6 kHz Select Setup (Signalling tab) Both ET
Signalling Out
O/P tone level
−10 dB to −28 dB
(2 dB steps)
Slider Setup (Signalling tab) Both ET
SNMP
Setup ‘Communities’
parameters (3 entries)
Plain text (password) Enter
SNMP (SNMP button,
TM tab)
TM ET
SNMP
Setup ‘System’
parameters (4 entries)
Plain text (info) Enter
SNMP (SNMP button,
TM tab)
TM ET