IGS6-10 GSM Interface Unit Siemens Add-on Modem for Sintony 60 Configuration Manual Fire Safety & Security Products Siemens Building Technologies
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. © 2007 Copyright by Siemens Building Technologies Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor.
Contents 1 Product description ................................................................................5 2 Technical data .........................................................................................6 3 Connections ............................................................................................7 4 4.1 4.2 4.3 4.4 4.5 Pre-installation requirements ................................................................8 Cellular account .........................................
Siemens Building Technologies Fire Safety & Security Products 12.
Product description 1 Product description The IGS6-10 is a GSM add-on modem. It connects to the Sintony bus and can function as a second dialer or backup dialer to the one in the control panel. When an event or alarm takes place the unit can either report to a central station or send an SMS message to a cellular phone. The following reporting media can be used simultaneously: Reporting media Reporting format TCP/IP CID GPRS CID GSM SMS Features z Full report for all the events of the IC60.
Technical data 2 Technical data Radio frequency Operating frequency 850 MHz, 900 MHz, 1800 MHz, 1900 MHz Output power Class 4 EGSM850: 2 W Class 4 EGSM900: 2 W Class 1 EGSM1800: 1 W Class 1 EGSM1900: 1 W GPRS multi-slot class 12 Modem Type GSM Quad-Band Internal Antenna Tri-Band Communication services TCP/IP Stack access via AT commands Internet services TCP, UDP, HTTP, FTP, SMTP, POP3 GSM Report Modes TCP/IP over CID GPRS over CID GSM over SMS Interfaces Antenna connector U.
Connections 3 Connections 1 NET: turns green when there is communication with TCP/IP server. Status LEDs BUS: blinks yellow on BUS communication with control panel. FAIL: Blinks or stable in red on network error (problem with SIM card, GSM network…). 2 SIM card holder SIM card used for the GSM modem. 3 Antenna Cellular phone antenna connector. 4 Tamper Switch Activates alarm if cover is removed. 5 Program Connector Connector for connecting the inputs and outputs.
Pre-installation requirements 4 Pre-installation requirements 4.1 Cellular account You need to open a cellular account with your cellular service provider to enable the cellular gateway module on your unit. On opening the account you receive the following: – A cell-phone number – GSM/GPRS SIM card 4.2 SIM card When ordering the GSM/GPRS SIM card, be sure to specify to the cellular service provider that the SIM card needs to be activated for GPRS data services (unlocked).
Installation 5 Installation 5.1 Configuration software 1. Double Click the installation file. Î The InstallShield Wizard opens. 2. Choose the destination location. 3. Click Next. Î 4. The installation starts. After the installation click Finish. Î The configuration software IGS6-10 is installed. 9 Siemens Building Technologies Fire Safety & Security Products 12.
Installation 5.2 Unit z Before installing the hardware we strongly recommend that you pre-program the unit. This is done using a PC or a laptop running the configuration program and using the USB cable supplied. z If the GSM unit is installed as a backup module, it should be installed at another location than the panel. Disconnect the mains and the backup battery. 1. Choose a suitable location for the unit within 1 to 20 meters from the IC60.The location must be within the secured area. 2.
Configure the unit 6 Configure the unit 6.1 Prerequisites z To ensure reporting disable the setting "No Keypad Indication if Armed": P25E13E 5E in the IC60. z Disable the setting: P168E1-16E 4E in the IC60. z Starting the software is only possible if the IGS6-10 modem is connected to the PC. 6.2 Starting the software 1. On the desktop, double-click the icon 2. Select a language. 3. Click the Next button. Î .
Configure the unit 6.3 Configuration methods There are 2 ways to configure the modem: – Local control via COM: for configuration via local PC (USB). – Control modem via Data Link: for remote configuration via GSM data call 1 2 Fig. 1 6.3.1 Configuration method Local control via COM Fig. 2 Configuration method: Local control via COM Port Prerequisites: z The USB cable is connected. 1. Start the program. 2. Press the button Local control via COM (see Fig. 1). 3. Press Next.
Configure the unit 6.3.2 Remote mode configuration Disconnect the master unit (the modem you are dialing from) from the keypad bus of the IC60. Fig. 3 Configuration method: Remote mode configuration Prerequisites: z The SIM card has been inserted in both modems. z A network connection is established. z The access code is available. Before making a remote configuration, a local configuration has to be made using the USB cable (see chapter 6.4.1: Local control via COM). 1. Start the program. 2.
Configure the unit 6.4 Protocols The following protocols can be used simultaneously: Reporting media Reporting format Reporting priority Symbol Section TCP/IP CID 1 6.4.1 GPRS CID 2 6.4.2 GSM SMS 3 6.4.3 If both GSM and TCP/IP protocols are selected, the data will be sent only via TCP/IP. If TCP/IP fails, the data will be sent via GSM. 1. Select the required protocols from the Available protocols. 2. Move it to the Selected protocols by pressing Î .
Configure the unit If there is a network error (see section 3: Connections), this window pops up automatically. 4. Click OK. Î The window will be closed 15 Siemens Building Technologies Fire Safety & Security Products 12.
Configure the unit 6.4.1 TCP/IP Prerequisites: z APN (see section 4.3: TCP / IP) of your service provider. z Domain name or an IP address. 1. Click the Î button. The window Internet configuration will open: Fig. 4 Internet Configuration Button or Field Description Access point name Displays the internet service provider (APN address) Event’s table Displays the available events to trigger the IGS6-10 modem. Add Add a new entry to the list. Remove Removes an unwanted number.
Configure the unit Independently If you want the IGS6-10 modem unit to operate independently of the PSTN of the control panel: 4. Uncheck the checkbox Only while PSTN Fail/Dialer Failure! Î The IGS6-10 unit will transmit the events together with the telephone line of the control panel. . 5. To add new IP addresses click the button 6. Enter a 4 digit ID number for the IGS6-10 modem in the account field. 7. In the next field enter a domain name or an IP address. 8. Click the button Î 9. .
Configure the unit Fig. 5 Events in simple mode There are two modes: z Simple mode: The available events list has only common events (see Fig. 5). z Advanced mode: The available events list has all events (Fig. 6). Fig. 6 Events in advanced mode 18 Siemens Building Technologies Fire Safety & Security Products 12.
Configure the unit 11. Choose a mode. 12. Double-click an event from the Available events list -ORSelect one and then click the button Î . Multiple events are now shown in the field Events to send. Any one of these events causes the IGS6-10 modem (if enabled) to transmit the event information. 13. To load a configuration: click the button . 14. To save the current configuration on your PC: click the button . You can make multiple configurations and save them on your PC.
Configure the unit 6.4.3 SMS configuration 1. Click the button Î The window SMS configuration opens: Fig. 8 2. . SMS configuration Configure the window SMS configuration as described in section 6.4.1. Exception: – Entry of APN not required. – Instead of a domain name or IP address you have to enter a telephone number. The SMS texts are in standard text and in English only. 20 Siemens Building Technologies Fire Safety & Security Products 12.
Configure the unit 6.5 Remote access configuration In this window you can setup the remote configuration. There are 2 security levels: z Only password z Password and telephone number. The telephone number will be used to get connection from the local unit to this unit, in order to figure this unit remotely. Make sure that your telephone can display the incoming phone number. 1. Click the button Î . The window Remote access configuration opens: 2.
Configure the unit 4. Enter the desired password (max. 14 characters). 5. If the authentication requires a password and a phone number, press the button Check password and phone number. Î The window Add phone number opens: 6. Enter the desired password (max. 9 characters). 7. Enter the phone number. 8. To erase the password at this entry remove the phone number from the list. 9. Click the button Î . You will get back to the configuration window.
Configure the unit 6.6 Fast SMS configuration This is the window to customize the SMS that will be triggered at Input 1. When Input 1 is shorted to ground (pulse), the custom SMS will be sent to the phone number entered in the SMS configuration window. If the SMS protocol is not selected in the field Selected protocols, then no SMS will be sent. As an additional feature, when this input is shorted to ground, an event "General Alarm" will be sent in CID (number 140), beside the custom SMS.
Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.siemens.com/homesecurity Document no. A6V10075156 Edition 12.2007 © 2007 Copyright by Siemens Building Technologies Data and design subject to change without notice. Supply subject to availability.