User Manual Part 3

System diagnostics
8.2 Reader diagnostics with SLG STATUS
SIMATIC RF300
8-2 System Manual, Release 04/2006, J31069 D0166-U001-A2-7618
8.2 8.2 Reader diagnostics with SLG STATUS
The SLG STATUS command can be used to scan the status and diagnostics data of the
reader.
SLG STATUS (mode 01), UDT110
HW ASCII Type of hardware
(31 to 38 hex)
HW-V Binary
value
HW version
0 to FF hex
0 to FF hex
= Version (high byte): Unused
= Version (low byte)
Url-V Binary
value
Version of loader
0 to FF hex
0 to FF hex
= Version (high byte)
= Version (low byte)
FW ASCII
format
Type of firmware
FW-V Binary
value
Firmware version
0 to FF hex
0 to FF hex
= Version (high byte)
= Version (low byte)
TR Binary
value
Type of driver "1" = 3964R
TR-V Binary
value
Version of driver
0 to FF hex
0 to FF hex
= Version (high byte)
= Version (low byte)
SS Binary
value
RS 232 / RS 422
01 hex
= RS 422
Baud Binary
value
Baud rate
01 hex
02 hex
05 hex
= 19.2 Kbaud
= 57.6 Kbaud
= 115,2 Kbaud
mtag Binary
value
Number of MDSes
(Multitag/Bulk) that can be
processed in the antenna field
= 1 with single-tag mode (param
= 0x05, 0x25)
ANT Binary
value
Status of antenna
01 hex
02 hex
= Antenna On
= Antenna Off
ANW Binary
value
Presence mode
0
01 hex
= Operation without presence
= Operation with presence (see
ANW-MELD signal)