User's Manual Part 2

Readers
5.1 RF 310-R
RF 300
5-6 System Manual, 05/2005, (4)J31069 D0166-U001-A1-7618, --
5.1.9 Technical data of the RF 310-R
Table 5-3 Technical data of the RF 310-R
Inductive interface to the transponder
Transmission frequency for power/data
13.56 MHz
Interface to SIMATIC S7-300
Required master module
RFID channels (RF 310-R)
Hybrid operation with other profiles
IQ-Sense, 2-wire polarity independent
8-IQ-Sense (6ES7 338-7XF00-0AB0)
Max. 2 possible per master module
Max. 4 Opto-BERO, 1x SIMATIC RF 310-R
Cable length, reader Max. 50 m (unshielded cable)
Read/write distances of reader See field data RF 310-R
Minimum distance between 2 RF 310-R units ≥ 400 mm
SLG data transmission rate
Read
Write
Approx. 50 bytes/s
Approx. 40 bytes/s
Traversal rate
Read
Write
Approx. 0.8 m/s (2 bytes)
Approx. 0.2 m/s (2 bytes)
Function Read, write, initialize transponder
Multi-tag no
Power supply via IQ-Sense master module 24 V DC
Indicators 2-color LED (operating voltage, presence, error)
Plug connector M12 (4-pin)
Housing
Dimensions (in mm)
Color
Material
55 x 75 x 30 (not including M12 connector)
anthracite
plastic PA 12
Fixing 4 x M5 screws
Ambient temperature
During operation
Storage and transport
-25°C to +70°C
-40°C to +85°C
Degree of protection per EN 60529
Shock to EN 60 721-3-7 Class 7 M2
Overall shock response spectrum type II
Vibration to EN 60 721-3-7 Class 7M2
IP65
50 g
1 g (9 to 200 Hz)
1.5 g (200 to 500 Hz)
Weight Approx. 200 g
Approvals
Radio to R&TTE guidelines EN 300 330,
EN 301 489
CE
UL
FCC