SIMATIC RF310M software
6.5 The functions in the "Tag" menu
SIMATIC RF310M Mobile Reader
32 Operating Instructions, 07/2007, J31069-D0191-U001-A1-7618
6.5.2 Requirements for operating the tag functions
To enable execution of the tag functions, you must set the memory size of the tag and the
minimum distances between the Mobile Reader and the tag.
Setting the memory size of the tag (Tag Type Selection)
Set the memory size of the tag using "Extras" > "Tag Type Selection" ( or <Ctrl+S>). See
also
Tag Type Selection (Page 46).
Distance limits to be observed between the Mobile Reader and the tag
The ranges listed in the table below are distance limits in the field maximum of the read
head.
Table 6-1 Ranges between Mobile Reader and transponders
Tag RF320T
RF340T
RF350T
Distance
limit (Sg)
4 mm
15 mm
20 mm
Minimum
distance
for further
tags
12 mm
45 mm
60 mm
Tag RF360T
RF370T
RF380T
Distance
limit (Sg)
22 mm
22 mm
18 mm
Minimum
distance
for further
tags
66 mm
66 mm
54 mm