597
Flow sensor QVE2000.0xx
QVE2100.0xx
for liquids in DN 10…25 pipes
· Vortex flow sensor made from fiber-glass-reinforced plastic
· Output signal: DC 0…10 V or 4…20 mA
· Flow range: 1.8 …150 l/min
· Used for temperature ranges: -15…+125 °C
· Operating voltage: DC 18…33 V (QVE2100…) or 11.5…33 V
(QVE2000…)
· Temperature-insensitive measuring principle
· No moving parts
· Low pressure loss
· Insensitive to soiling