User's Manual

B-14
MOBY U – Manual for Configuration, Installation and Service
(4) J31069-D0139-U001-A2-7618
The commands FORMAT, CREATE, WRITE, ATTRIB, UPDATE, COVER,
QUEUE-READ or QUEUE-WRITE were sent with illegal parameters.
FORMAT with illegal MDS name or MDS type
CREATE with illegal filename
WRITE/UPDATE with length of 0 (DLNG=0)
Illegal attribute
QUEUE-WRITE or QUEUE-READ with illegal option
COVER with illegal user (Only 0 or 1 are legal.)
The system data transferred with the LOAD command are wrong.
DLNG is parameterized incorrectly for LOAD.
Wrong data block specified or incorrectly parameterized
MOVE command not executed correctly. On the MDS, DIR + FAT
don’t match checksum.
The MOVE command cannot be executed. The checksum does not fit
DIR + FAT. The data memory has probably exited the transmission win-
dow while system operations (e.g., write DIR + FAT) were being executed
or the data structure of the MDS is defective.
The RESET command was transferred to the filehandler with the wrong
parameters.
Check bytes 11 to 17 of the telegram.
WRITE command:
No longer enough memory space available on the MDS.
The data will not be completely written to the MDS.
CREATE command:
When a file is set up, no data block can be reserved for it.
No more memory blocks are free.
The MDS could not be identified by the filehandler. Format the MDS again.
The logically addressed address is not within the file. The FAT has an error.
The MDS must be formatted again.
The data memory has been locked with the COVER command. A
write–access command (e.g., UPDATE, CREATE) would destroy the data
memory layout and is thus rejected.
D0 05:
D0 07:
D0 09:
D0 14:
D0 15:
D0 18:
D0 22:
Error Messa
g
es