Cerberus™ PRO Fire control panel FC722 Compact, pre-assembled fire control panel with integrated, user-friendly operating unit.
Features and Functions System The diagrams have been simplified and do not include additional network hardware or security components. Permissible applications are described in the A6V101039439 Network Security Guidelines document. Contact your Siemens IT security expert for more information. System overview Fig.
1 Remote access with Cerberus-Remote 2 FS cloud applications 3 Customer network 4 Management platform 5 Remote access to management platform 6 Remote access with Cerberus Mobile 7 Router + firewall + virtual private network 8 Fire damper with actuator Transmission of a fault signal Transmission of an alarm signal You will find a detailed labeled version of the diagram above along with further information in the A6V10332842 planning guide, see chapter 'Product documentation'.
Networking of fire control panels The diagrams have been simplified and do not include additional network hardware or security components. Permissible applications are described in the A6V101039439 Network Security Guidelines document. Contact your Siemens IT security expert for more information. Up to 32 control panels and terminals can be linked to form one C-WEB network. If the C-WEB network is connected to a danger management system via BACnet, up to 16 control panels and terminals can be networked.
Fig. 3: Backbone 1 Remote access with Cerberus-Remote 2 FS cloud applications 3 Customer network 4 Management platform 5 Remote access to management platform 6 Remote access with Cerberus Mobile 7 Router + firewall + virtual private network Transmission of a fault signal Transmission of an alarm signal You will find a detailed labeled version of the diagram above along with further information in the A6V10332842 planning guide, see chapter 'Product documentation'.
Control panels General features and functions ● Fast Ethernet interface for a heterogeneous network ● Processes the signals of the Cerberus PRO detector series FD720 ● Floor repeater displays, terminals and alarm devices on the C-NET detector line with power supply via C-NET ● Interface to Siemens danger management system ● Slots for RS232 and RS485 serial interfaces ● All detector lines are monitored for ground faults ● Integrated degraded mode function ● Freely configurable, time-dependent controls with o
FC722-ZZG Housing (Standard) Detector line (C-NET), 1.5 A ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit ● 70 W power supply ● Connect X200 Gateway ● Max. battery capacity 12 Ah Options of the operating unit ● Event printer FTO2001-A1 ● Key switch (Kaba) FTO2005-C1 ● Key switch (nordic) FTO2006-B1 FC722-YZ Housing (Standard) Detector line (C-NET) ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit (+LED indicator) ● 70 W power supply ● Max.
FC722-ZE Housing (Comfort) Detector line (C-NET) ● 252 addresses ● 2 loops/4 stubs Properties ● Operating unit ● Operating add-on (2xLED indicator) ● 150 W power supply ● Max.
FH7203-Z3 Housing (Comfort) ● ● ● ● Empty housing for free use 430 x 796 x 165 mm E.g., for extra batteries, operating add-ons, or event printers Space for the following battery configurations: – 2x FA2005-A1 (17 Ah) or ● FTO2001-A1 Event printer ● ● ● DL3750+ – 2x BAT12-25 (25 Ah) The mounting kit for the batteries FHA2061-A1 must be ordered separately.
Design Function elements Operating unit The following elements are available on the operating unit: ● CPU module and electronics ● Ethernet connection ● Slots for RS232 and RS485 modules ● Space for 'Kaba' or 'nordic' key switch ● Space for event printer (depending on version) Periphery board From IP8, the fire control panels can be ordered with a periphery board with a 0.5 A or 1.5 A output current per C-NET line. To convert existing fire control panels, the periphery board with 1.
Setup FC722 inside housing (Standard) Fig. 4: FC722 Standard Position Designation Type Comment Items 1-5: Basic equipment. The periphery board (2 loops, P) can be ordered separately to convert the station to the 1.5 A C-NET line. Basic equipment 1 Housing (Standard) FH7202-Z3 2 Periphery board (2 loops) FCI2002-A1 Periphery board (2 loops, P) FCI2023-A1 3 Power supply (70 W) FP2015-A1 4 Mains terminals on TS35 DIN rail - Space for socket, relay modules, etc.
Position Designation Type Comment Extensions 7 Relay module Z3B171 Relay for fire controls 8 Event printer FTO2001-A1 For logging events 9 Key switch (Kaba) FTO2005-C1 For operating access authorization Key switch (nordic) FTO2006-B1 10 Mounting plate FHA2007-A1 e.g.
FC722 inside housing (Comfort) Fig. 5: FC722 Comfort Position Designation Type Comment Items 1-5: Basic equipment. The periphery board (2 loops, P) can be ordered separately to convert the station to the 1.5 A C-NET line. Basic equipment 1 Housing (Comfort) FH7203-Z3 2 Periphery board (2 loops) FCI2002-A1 Periphery board (2 loops, P) FCI2023-A1 3 Power supply (SV 24 V-150 W) V24230-Z6-A5 4 Mains terminals on TS35 DIN rail - Space for socket, relay modules, etc.
Position Designation Type Comment Extensions 7 Relay module Z3B171 Relay for fire controls 8 Event printer FTO2001-A1 For logging events 9 Key switch (Kaba) FTO2005-C1 For operating access authorization Key switch (nordic) FTO2006-B1 10 Mounting plate FHA2007-A1 e.g.
Type Overview Housing (Standard) Type FC722-ZZ Housing (Comfort) FC722-YZ Number of C-NET addresses FC722-ZA FC722-ZE 252 Number of lines: Loops (with loop extension) or 2 (4) Stubs (with loop extension) 4 (8) Power supply 70 W 150 W Battery size 12 Ah 25 Ah Indicator groups with one red/green and one yellow LED each - 24 - 48 15 Smart Infrastructure A6V10206525_l_en_-2021-10-22
Details for ordering Control panels Type Designation Weight Order number FC722-ZA Fire control panel (2-loop) 14.958 kg S54400-C29-A2 FC722-ZA Fire control panel (2 loops, P) - S54433-C113-A3 FC722-ZE Fire control panel (2-loop) 15.207 kg S54400-C29-A1 FC722-ZZ Fire control panel (2-loop) 8.576 kg S54400-C29-A5 FC722-ZZ Fire control panel (2 loops, P) 8.629 kg S54433-C113-A1 FC722-ZZG Fire control panel (2 loops, P, X200) 9.
Type Designation Weight Order number - Spare printer reels (10 reels) 0.090 kg A5Q00017619 FTO2005-C1 Key switch (Kaba) 0.083 kg A5Q00010113 FTO2006-B1 Key switch (nordic) 0.046 kg A5Q00010129 Z3B171 Relay module 250 V AC / 10 A (1 relay) 0.042 kg 4843830001 Auxiliary power supply Type Designation Weight Order number FP2004-A1 Power supply kit (150 W, A) for ENcompliant installation in empty housing 1.286 kg A5Q00020825 FP2005-A1 Power supply kit (150 W, B) for extension 1.
Batteries Type Designation Weight Order number FA2004-A1 Battery (12 V, 12 Ah, VdS) 3.750 kg A5Q00019354 FA2005-A1 Battery (12 V, 17 Ah, VdS) 5.700 kg A5Q00019677 BAT12-25 Battery (12 V, 25 Ah, VdS) 7.8 kg S54302-Z102-A1 FHA2061-A1 Mounting kit for batteries ‒ S54400-B91-A1 FHA2062-A1 Cable tie for batteries ‒ S54400-B92-A1 Type Designation Weight Order number FCA2033-A1 License key (S1) 0.010 kg S54400-P154-A1 FCA2034-A1 License key (S2) 0.
Product documentation Title Document ID System documentation System description A6V10210355 Product data A6V10210368 Planning A6V10210362 Mounting/Installation A6V10210390 System data sheet FS720 – Fire detection system A6V10227649 Data sheets FC721 - fire control panel A6V10203220 FC722 - fire control panel A6V10206525 FC723 - fire control panel for modernization A6V10379246 FC724 - fire control panel A6V10207176 FC726 - fire control panel (modular) A6V10263277 FT724 - fire terminal
Technical data Fire control panel (2 loops)/(2 loops, P) FC722 in housing (Standard) Supply Inputs / outputs Mains voltage AC 97…127 V / AC 196…253 V Power supply 70 W Operating voltage DC 20.5…28.6 V Operating current Max. 2.5 A Battery capacity 2x 12 V, max. 12 Ah Battery monitoring Yes Network monitoring Yes Connectable detector series Cerberus PRO (C-NET) Number of addresses Max.
Fire control panel (2 loops)/(2 loops, P) FC722 in housing (Standard) Ambient conditions Mechanical data Operating temperature -8…+42 °C Storage temperature -20…+60 °C Air humidity (no condensation permitted) ≤95 % rel.
Fire control panel (2 loops)/(2 loops, P) FC722 in housing (Comfort) Supply Inputs / outputs Mains voltage AC 115 / 230 V +10/-15 % Power supply 150 W Operating voltage DC 21…28.4 V Operating current Max. 5 A Battery capacity 2x 12 V, max. 25 Ah Battery monitoring Yes Network monitoring Yes Connectable detector series Cerberus PRO (C-NET) Number of addresses Max.
Fire control panel (2 loops)/(2 loops, P) FC722 in housing (Comfort) Ambient conditions Mechanical data Operating temperature -8…+42 °C Storage temperature -20…+60 °C Air humidity (no condensation permitted) ≤95 % rel.
Issued by Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a CH-6300 Zug +41 58 724 2424 www.siemens.com/buildingtechnologies Document ID A6V10206525_l_en_-- Edition 2021-10-22 © Siemens Switzerland Ltd, 2007 Technical specifications and availability subject to change without notice.