Specification

Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R
Max.
1-Pole QP Dimensions Dimensions
Amp No. of No. of Max. Catalog List Std. (inches) Catalog List Std. (inches)
Rating Spaces Circuits 2-Poles Number Price $ Pkg. H W D Number Price $ Pkg. H W D
100 10 20 4 E1020MB1100FCGP
햸햽
494.00 1 14 3/4 12 3/8 3 7/8 ————
100 12 24 6 E1224ML1100FCU 265.00 1 14 3/4 12 3/8 3 7/8 ————
125 8 16 4 E0816ML1125FCU
158.00 1 14 3/4 12 3/8 3 7/8 W0816ML1125CU
264.00 1 14 3/4 12 1/8 4 1/4
125 8 16 4 E0816ML1125SCU 154.00 1 14 3/4 12 3/8 3 7/8 ————
225 4 6 2 ——1— W0406ML1225CU
396.00 1 23 10 4 1/8
200 4 4 2 ——1— W0404MB1200CT
햻햽
823.00 1 20 11 1/8 4 3/4
Siemens / Speedfax Previous folio: 1-9
Siemens Power Distribution & Control, SPEEDFAX™ 2007-2008 Product Catalog
Discount Schedule RESI
1-9
1
LOAD CENTERS &
CIRCUIT BREAKERS
EQ
®
Load Centers
Small Circuit Load Centers
Selection/Wiring Diagrams
Features
Wiring Diagrams
100,000A IR
4–16 circuits, 100–225 Amperes
1-Phase, 3-Wire, SN 120/240 Volts AC
70 amp maximum breaker.
Will not accommodate 2-pole GFCI or circuit breaker with
shunt trip.
Suitable for use as service equipment when a main breaker
(100A maximum) is back-fed in a branch position and used
with main breaker retainer clip (Cat. No. ECMBR1).
100 amp maximum breaker.
Suitable for use as service entrance equipment when a main
breaker (125A maximum) is back-fed in a branch position and
used with main breaker retainer clip (Cat. No. ECMBR1).
Suitable for use as service entrance when not more than six
main disconnecting means are provided, and when not used as
lighting and appliance branch circuit panelboard. Check local
codes and restrictions.
Two Q115 and one Q230 breaker included.
W0408L1125SPA50 provided with factory installed QF50 and
ground bar. W0408L1125SPA60 provided with factory installed
QF260 and ground bar.
Copper Bus load centers are recommended for those
applications where the environment may be severe
(i.e. farm and coastal areas).
2" HS Type hub provided.
Type QNR main breaker factory installed.
E0408ML1125
W0408ML1125
8-Poles Max
.
E0816ML1125
W0816ML1125CU
16-Poles Max
.
E1224ML1100FG
24-Poles Max
.
Main Lug and Main Breaker with Copper Bus
햷햺
Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R
Max. Catalog Number
1-Pole QP Replace Suffix F Dimensions Dimensions
Amp No. of No. of Max. (Flush) with S for List Std. (inches) Catalog List Std. (inches)
Rating Spaces Circuits 2-Poles Surface Mounting Price $ Pkg. H W D Number Price $ Pkg. H W D
100 12 24 6 E1224ML1100FG
261.00 1 14 3/4 12 3/8 3 7/8 ————
125 4 8 2 E0408ML1125F
햳햵햶
81.00 5 12 5/8 6 5/8 3 1/2 W0408ML1125
햳햴햵
150.00 5 12 1/4 6 4 1/4
125 4 8 2 ———— — — W0408L1125SPA50
햴햵햹
600.00 1 12 1/4 6 4 1/4
125 4 8 2 ———— — — W0408L1125SPA60
햴햵햹
630.00 1 12 1/4 6 4 1/4
125 8 16 4 E0816ML1125F
145.00 1 14 3/4 12 3/8 3 7/8 ————
Features/Applications
EQ Load Centers with main lugs feature a combination trim box in one package.
Interiors offer removal in seconds
Single phase
One piece bus bar construction designed
for use only with circuit breakers
UL Listed
UL listed on 60/75°C conductors
(see equipment markings for applications)
Positive load side circuit breaker hook rails
Outdoor Type 3R devices use HS Type
hubs
100,000A IR
4–16 circuits, 100–125 Amperes
1-Phase, 3-Wire, SN 120/240 Volts AC
Main Lugs with Aluminum Bus
E0816ML1125(F,S)CU
E0408ML1125(F,S)
Sect_01_Speedfax2007 5/7/07 9:27 AM Page 1-9