Connection of the cables
Make sure that the wiring is correct before you start up the device.
Supply voltage
CAUTION
Safety extra low voltage
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited
Power Source (LPS). (This does not apply to 100 V...240 V devices.)
This means that only SELV / LPS complying with IEC 60950‑1 / EN 60950‑1 / VDE 0805‑1
must be connected to the power supply terminals, or the power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code (r)
(ANSI / NFPA 70).
7.2.3 Technical specifications
Table 7-5 Technical specifications of the transponder RTLS4060T
6GT2700-6DE03
Product name SIMATIC RTLS4060T
PULSE radio frequencies (localization)
Wireless method IEEE 802.15.4-2011 UWB
Transmission speed 6.8 Mbps
Operating frequency rated value 3100 MHz … 4800 MHz
6000 MHz … 7000 MHz
Transmit power 0.037 mW (-41.3 dBm/MHz)
Range Max. 30 m
Accuracy of the localization 0.2 m
Antennas Built-in UWB antenna
PHASE radio frequencies (communication and optional local‐
ization)
Wireless method IEEE 802.15.4
Transmission speed 1 Mbps
Operating frequency rated value 2400 ... 2480 MHz
Transmit power 0.00025 ... 100 mW
Range Max. 500 m
Accuracy of the localization 1 m
Transponder
7.2 SIMATIC RTLS4060T
136 System Manual, 04/2019, C79000-G8976-C577-01