User Manual

Appendix
A.1 Process data and data sets
SIRIUS ACT 3SU1 pushbuttons and signaling devices
276 System Manual, 02/2015, A5E03457306020A/RS-AB/002
A.1.1.2
IO-Link communication parameters
Parameter Page 1 - IO-Link communication parameters
Table A- 2 Parameter Page 1
Address
Parameter name
Access
Description
0x00
Master Command
w
0x01 Master Cycle Time r / w
0x02
Min. Cycle Time
r
0x6e
0x03 M-Sequence Capability r 0x11
0x04
IO-Link Revision ID
r / w
0x11
0x05
Process data IN
r
0x50
0x06
Process data OUT
r
0x00
0x07
Vendor ID 1
r
0x00
0x08
Vendor ID 2
r
0x2a
0x09
Device ID 1
r / w
0x0c
0x0A
Device ID 2
r / w
0x03
0x0B
Device ID 3
r / w
0x01
0x0C
Function ID 1
r
0x00
0x0D
Function ID 2
r
0x00
0x0E
Reserved
r
0x0F
System Command
w