Quick Guide

-23
Controlling the Projector Using RS-232C or Telnet
User Name Setting
([4]User Name)
Carrying out security protection using user name.
11
11
1 Enter “4” and press the “Enter” key.
22
22
2 Enter user name and press the “Enter” key.
Display set user name (*).
Note
User name can be up to 8 characters.
You can input the characters below :
a-z, A-Z, 0-9, -, _
In the default state, user name is not set.
Password Setting
([5]Password)
Carrying out security protection using password.
11
11
1 Enter “5” and press the “Enter” key.
22
22
2 Enter password and press the “Enter” key.
Display set password (*).
Note
Password can be up to 8 characters.
You can input the characters below :
a-z, A-Z, 0-9, -, _
In the default state, the password is not set.
setup>4
User Name :
Please Enter : XG-MB70X
(change) —> XG-MB70X
1
2
*
setup>5
Password :
Please Enter :
sharppj
(change) —> sharppj
1
2
*
RS-232C Baud Rate Set-
ting ([6]RS-232C Baud Rate)
Setting of baud rate for RS-232C (COMPUTER and
PROJECTOR) terminals.
11
11
1 Enter “6” and press the “Enter” key.
22
22
2 Select and enter the number 0 or 2 and press
the “Enter” key.
Display set baud rate (*).
Note
Set the projector’s baud rate to the same rate as
that used by the computer.
Projector Name Setting
([7]Projector Name)
It is possible to assign a projector name.
11
11
1 Enter “7” and press the “Enter” key.
22
22
2 Enter projector name.
Display set projector name (*).
Note
Projector name can be up to 12 characters.
You can input the characters below :
A-Z, 0-9, -, _, (,), space
(When “a-z” are input, they are converted to “A-Z”
automatically.)
It is the same as the name which can be con-
firmed or set, using RS-232C commands “PJN0”,
“PJN1”, “PJN2” and “PJN3”.
setup>6
note: It sets both RS-232C (COMPUTER) and RS-232C (PROJECTOR).
0 ... 9600 bps
2 ... 115200 bps
Baud Rate Select[0, 2] :2
RS-232C Baud Rate : 115200 bps
1
2
*
setup>7
Projector Name : XG-MB70X
Please Enter : MY XG-MB70X
(change) —> MY XG-MB70X
1
2
*
XG-MB70X_E_P20_30.p65 04.8.6, 2:25 PM23