Instruction manual
54
The cash register provides various options so you can use the register to suit your sales needs.
In this section, you can program the following features (parameters within parentheses indicates default setting):
• Power save mode (entering the power save mode after 30 minutes)
• Logo message print format (graphic logo only)
• High amount lockout (HALO) for cash in drawer (CID) (9999999.99) (sentinel) - When the cash in drawer
reaches the amount programmed, the sentinel mark “X” will be displayed at the leftmost position on the lower
line of the operator display.
• Thermal printer density (standard density)
• RS-232C interface
• Language selection (English)
• Training clerk specification (none)- If you specify a clerk code who is trained for use on this cash register, the
cash register will go into training mode when the clerk code is registered for sales entries. The sales
operations done by the trained clerk do not affect sales totals. For details, refer to TRAINING MODE section.
Power save mode
* Item: Selection: Entry:
A Entering power save mode Yes* 0
when time is displayed No 1
B-D Time(min.) to entering power save mode 001-254 or 999
since no operation is made (Default 030)
When 999 is set for B to D, entering into power save mode is inhibited.
Logo message print format
You can select the number of lines for your logo message, and the position to print it on receipt.
For details of the logo message type, please refer to “Logo messages” on page 46.
*A: Logo message type
0: Header 3-line message without graphic logo
1: Graphic logo only (default)
2: Footer 3-line message with graphic logo
3: Header 6-line message
4: Header 3-line message with graphic logo
5: Header 3-line message and footer 3-line message
s @
*A
As
To set “0”
11
s
10
@
0060
sA
PrintKey operation example
s @
*ABCD
As
10
Various Function Selection Programming 2
3