Owner`s manual

5Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. K • 9/08
E. Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750
o
C, shall be considered
non-combustible materials.
F. Combustible Materials Speci cation
Materials made of or surfaced with wood, compressed paper,
plant bers, plastics, or other material that can ignite and
burn, whether ame proofed or not, or whether plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with National Electric Code ANSI/NFPA
70-latest edition or the Canadian Electric Code CSA
C22.1.
A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.