Fire hazard.
Do NOT change the valve settings.
This valve has been preset at the factory.
Changing valve settings may result in re
hazard or bodily injury.
HIGH ALTITUDE INSTALLATIONS
U.L. Listed gas appliances are tested and approved
without requiring changes for elevations from 0 to
2000 feet in the U.S.A. and Canada.
When installing this appliance at an elevation above
2000 feet, it may be necessary to decrease the
input rating by changing the existing burner ori ce
to a smaller size. Input rate should be reduced by
4% for each 1000 feet above a 2000 foot elevation
in the U.S.A., or 10% for elevations between 2000
and 4500 feet in Canada. If the heating value of the
gas has been reduced, these rules do not apply. To
identify the proper ori ce size, check with the local
gas utility.
If installing this appliance at an elevation above 4500
feet (in Canada), check with local authorities.
CHECK FOR GAS LEAKS
Explosion Risk
Fire Risk
Asphyxiation Risk
• Check all ttings and connections.
Do not use open ame.
After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available,
non-corrosive leak check solution. Be sure
to rinse off all leak check solution following
testing.
Fittings and connections may have
loosened during shipping and handling.
WARNING
WARNING
A small amount of air will be in the gas supply lines.
When rst lighting appliance it will take a short time for
air to purge from lines. When purging is complete the
appliance will light and operate normally.