9.10 Removing the electronics unit
The control unit must be isolated from the mechanism.
› First move the plotter head to the
TOOL CHANGE
position if the
circuit board plotter is still attached.
› Now use the traverse buttons to move the crossbar to the centre of
the machine base plate.
Note: The head must not be in either the tool change or Home
position and the limit switches must have been cleared.
› Switch off the circuit board plotter and disconnect the device from the
mains by removing the mains connector.
fig. 58: Position of the screws for
removing the electronics
unit from the
LPKF ProtoMat 95s/II
mechanism
› Undo the electric connections between the mechanism and the
control unit.
› Tilt the circuit board plotter towards the head.
› Undo feet 1, 2, 3, 4 and the Allen screws 5, 6 on the underside of the
machine.
› Remove the cover with the limit switches.
The control unit has now been released.
Danger! Check that the machine is disconnected from the mains by
removing the mains connector.