Specifications
Appendix
74 ProtoMat 95s/II
BoardMaster
switches from automatic tool change to manual change if
the “Dispense” or “Vacuum” production phase is selected since it is not
possible to change the various dispense and vacuum needles
automatically. In addition the operator must attach the brakket to the
plotter head.
Caution! Revert to the automatic tool change mode for drilling,
engraving or milling. The bracket must be removed as otherwise
the plotter would be damaged by the automatic tool change.
9.9 Switching the device voltage, electrical fuses
Danger! Make sure that the mains connector is removed before
working on the fuses or opening the device.
The LPKF
ProtoMat
95s/II has both primary fuses and secondary fuses.
The main (primary) fuses (slow) are in the control unit power connection
and can be accessed from the outside.
Caution! Make sure that both fuses are replaced when switching to
another line voltage.
Both fuses must have the same rating.
fig. 57: Voltage setting and fuses
The secondary fuses are inside the control unit.
The control unit must be removed from the mechanism before replacing
the fuses. Proceed as described under „Removing the electronics unit“
on page 75.