Operator`s manual

918496/GP0313 95
Towing AL 300 Series
Machines
Preparation
1. Perform the “Mandatory
Safety Shutdown Procedure”
on page 10.
2. Disconnect hoses (B) and the
electrical connector from the
motor. Cap the ends of the
hoses to prevent hydraulic
fluid loss.
3. Remove bolts (A, Fig. 59)
securing drive motor (C).
Note: Record the position of the hoses for
re-assembly.
4. Remove hydraulic motor (C) from the
axle. Support the motor during towing.
5. After towing the machine, replace the
motor in the axle and secure the motor
with bolts (A).
6. Reconnect hoses (B) and the electrical
connector to the motor.
Note: Reconnect hoses (B) in the same
positions where they were removed.
Towing AL 500 and AL 400
Series Machines
Preparation
1. Perform the “Mandatory Safety Shut-
down Procedure” on page 10.
2. Tilt up the operator’s platform. See
“Tilting Up the Platform” on page 107.
3. Loosen the bypass valve bolts (R, Fig.
60) three turns.
Do not loosen the bypass valve bolts more
than three turns. The bypass valve bolts can
come out of the pump, resulting in a rapid loss of hydraulic fluid.
4. Tilt and secure the operator’s platform back into the operating position. See
“Tilting the Platform Down” on page 108.
Figure 59 – Hydraulic Motor
Removal (AL 300 Series)
A
B
A
C
Figure 60 – Hydraulic Pump
Bypass Valve (AL 400\500
Series)
R
CAUTION