RS-232C command table
How to read the command table
Command: Command eld (See page 35.)
Direction: W When the “Parameter” is set in the parameter eld (see page 35), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter eld. (See page 35.)
Parameter: Parameter eld (See page 35.)
Reply: Response (Returned value)
* : When POWER SAVE MODE is set to OFF:
“●/○” : Indicates a command which can be used in standby mode or when the power is on.
“–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
When POWER SAVE MODE is set to ON:
“●” : Indicates a command which can be used in standby mode or when the power is on.
“○/–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
Power control/Input mode selection
Function
Command Direction
Parameter Reply Control/Response contents *
POWER CONTROL POWR W 0
Switches to standby mode.
●
1 Returns from standby mode.
R 0 Standby mode
1 Normal mode
2 Input signal waiting mode
INPUT MODE SELECTION INPS W 0 Toggle change for input mode. Terminals not selected in INPUT SELECT
cannot be selected.
2 D-SUB[RGB]
“ERR” when other than RGB is selected for D-SUB of INPUT SELECT.
3 D-SUB[COMPONENT]
“ERR” when other than COMPONENT is selected for D-SUB of INPUT
SELECT.
10 HDMI1
13 HDMI2
14 DisplayPort
21 OPTION
“ERR” when nothing is attached in the expansion slot.
24 APPLICATION
R 2 D-SUB[RGB]
3 D-SUB[COMPONENT]
10 HDMI1
13 HDMI2
14 DisplayPort
21 OPTION
24 APPLICATION
SCREEN menu
Function
Command Direction
Parameter Reply Control/Response contents *
Check the resolution
(other than D-SUB[COMPONENT])
PXCK R - Returns current resolution in the form of hhh, vvv.
○
Controlling the Monitor with a computer (RS-232C)