Operation Manual, Setup Guide for the Administrator, GB

12
1) Select [Fusing Temperature Settings] in the Fusing
Adjustment screen.
2) To change the fusing temperature setting, tap the [+]
and [-] key or use the 10-key pad appears when each of
the textboxes is tapped.
Example of Fusing Temperature Setting screen
Input range: [-10] to [10]
Default: [0] for each
Note:
To reset all items to [0], tap the [Return Entered
Values to Zero] key.
3) Tap the [Register] key to register the setting.
Note:
To reflect the settings, the machine needs to reboot.
When the [Register] key is tapped, a message
appears prompting you to reboot the machine.
4) Tap the [OK] key to reboot the machine.
1.4 Transfer
Select [Transfer] in the Image Quality Adjustment screen.
1.4.1 Primary Transfer Current Value Setting
This performs toner transfer adjustment by fine tuning
primary transfer current value.
1) Select [Primary Transfer Current Value Setting] in the
Transfer screen.
2) Select the colour to adjust and enter the desired value.
Input range: [-20] to [20]
Default: [0] for each
Note:
If image problems such as misalignment or streaks
occur due to usage in high humidity environment or
after a long period of non-use, increasing the value
may improve the image.
If ghost images (print memory) appear due to usage
in a low temperature, low humidity environment or
after a long period of non-use, decreasing the value
may improve the image.
3) Tap [Register] key to register the setting.
Note:
To reset all items to [0], tap the [Return Entered
Values to Zero] key.