Service manual
MX-CFX1 SIMULATION 9 – 2
3-32
Purpose
Setting (Adjustment)
Function (Purpose)
Used to set the adjustment value of the
inserter paper width detection level.
Section
Inserter
Operation/Procedure
1) Select an item corresponding to the adjustment content with [↑]
and [↓] keys on the touch panel.
2) Enter the adjustment value with 10-key.
3) Press [OK] key. (The set value is saved.)
Item Display Item Set range
A
MAX.
POSITION
Inserter tray width detection
adjustment value (Max. width)
0 - 1023
B POSITION 1
Inserter tray width detection
adjustment value (Adjustment
position 1)
0 - 1023
C POSITION 2
Inserter tray width detection
adjustment value (Adjustment
position 2)
0 - 1023
D
MIN.
POSITION
Inserter tray width detection
adjustment value (Min. width)
0 - 1023
A: 72
; MAX. POSITION
B : 200 ; POSITION1
C : 10 ; POSITION2
D : 100 ; MIN. POSITION
A:
SIMULATION NO.03-32
INSERTER TRAY VALUE SETTING
72
0 1023
OK
TEST
CLOSE