Owner's Manual

174
Device Control
These settings control devices installed on the machine. Touch the [Device Control] key and configure the settings.
Original Size Detector Setting
One of the five groups of standard original sizes shown
below can be selected for detection by the original size
detection function.
Select one of the keys and touch the [OK] key.
To disable detection of original sizes on the document
glass, select the [Cancel Detection at Document Glass]
checkbox and touch the [OK] key.
Disabling of Document Feeder
Use this setting to prohibit the use of the automatic
document feeder, such as when the feeder malfunctions.
(When the setting is enabled, scanning is still possible
using the document glass.)
To enable this setting, select the checkbox and
touch the [OK] key.
Original Feeding Mode
The following original feeding modes can be set to
operate by default in image send mode. When a mode is
frequently used, this saves you from having to select the
mode in the special modes each time it is used.
• Mixed Size Original (Same Width/Different Width)
• Slow Scan Mode
To use this setting, select the checkboxes of the
desired items and touch the [OK] key.
Disabling of Duplex
This is used to disable two-sided printing, such as when
the duplex module malfunctions.
To enable this setting, select the checkbox and
touch the [OK] key.
Disabling of Large Capacity
Cassette
(When a large capacity tray is installed.)
This setting is used to prohibit the use of the large
capacity tray, such as when the cassette malfunctions.
To enable this setting, select the checkbox and
touch the [OK] key.
Selections
Detectable original sizes
Document glass Document feeder tray
(automatic document
feeder)
AB-1 A3, A4, A4R, A5,
B4, B5, B5R
A3, B4, A4, A4R, B5,
B5R, 8-1/2" x 11",
8-1/2" x 14",
11" x 17"
AB-2 A3, A4, A4R, A5,
B5, B5R
216 mm x 330 m
(8-1/2" x 13")
A3, A4, A4R,
A5, B4, B5, B5R,
8-1/2" x 11",
11" x 17",
216 mm x 330 mm
(8-1/2" x 13")
AB-3 A4, A4R, A 5, B4,
8K, 16K, 16KR
A3, A4, A4R, A 5, B4,
8K, 16K, 16KR,
8-1/2" x 11",
11" x 17",
216 mm x 330 mm
(8-1/2" x 13")
INCH-1 11" x 17",
8-1/2" x 14",
8-1/2" x 11",
8-1/2" x 11"R,
5-1/2" x 8-1/2"
11" x 17",
8-1/2" x 14",
8-1/2" x 11",
8-1/2" x 11"R,
5-1/2" x 8-1/2", A4,
A3
INCH-2 11" x 17",
8-1/2" x 13"
(216 mm x 330 mm),
8-1/2" x 11",
8-1/2" x 11"R,
5-1/2" x 8-1/2"
11" x 17",
8-1/2" x 13"
(216 mm x 330 mm),
8-1/2" x 11",
8-1/2" x 11"R,
5-1/2" x 8-1/2", A4,
A3
If "Cancel Detection at Document Glass" is selected,
all originals placed on the document glass will be
treated as special size originals.
System Settings
Original Feeding Mode
Copy
Scan to HDD
Image Send
OK
Slow Scan Mode
Mixed Size Doc.
Same Width
Mixed Size Doc.
Different Width