Flat Panel Television User Manual
LD-14115-11
7. Timing characteristics of input signals
7-1-1. Timing characteristics
Parameter Symbol Min. Typ. Max. Unit Remark
Clock Frequency 1/Tc 60.0 81.0 85.0 MHz
Skew Tcsq –4 0 4 ns
【
Note1
】
Data enable 830 1080 1600 clock
signal
Horizontal period TH
10.0 13.3
-
µs
Horizontal period (High) THd 800 800 800 clock
1205 1250 2000 line Vertical period TV
12.1 16.7
-
ms
【
Note2
】
Vertical period (High) TVd 1200 1200 1200 line
【
Note1
】
Lvds (A port)– Lvds (B port) phase difference
【
Note2
】
In case of using the long vertical period, the deterioration of display quality, flicker etc. may occur.
1599
1600
1 3
24
1599
1600
2
1
THd
TH
TVd
TV
Tc
1 2 1200
DEA,DEB
DA
(RA,GA,BA)
DB
(RB,GB,BB)
DEA,DEB
Tcsq
DEA
DEB
1199