R PURIFICATEUR D'AIR MANUEL D'UTILISATION Free standing type Воздухоочиститель РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ENGLISH DEUTSCH РУССКИЙ LUCHTREINIGER GEBRUIKSAANWIJZING FRANÇAIS LUFTREINIGER BEDIENUNGSANLEITUNG NEDERLANDS AIR PURIFIER OPERATION MANUAL ENGLISH FU-W28E *Plasmacluster is a trademark of Sharp Corporation. FU-W28E.eng.indd 1 08.11.
Please read before operating your new Air Purifier The air purifier draws in room air from its air intake, lets the air pass through an Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through the HEPA filter if removes 99.97% of dust particles (as small as 0.3 microns.).
ENGLISH "Plasmacluster" technology Plasmacluster technology uses plasma discharge to produce and release the same positive and negative ions as those found in nature ("Plasmacluster ions"). This is a unique air cleaning technology of the SHARP CORPORATION for breaking down and eliminating such potential allergens as the fecal matter or corpses of aerial mites*1, viruses *2 and mold and bacteria *3 suspended in the air, and has been substantiated by third-party organizations both in Japan and overseas.
IMPORTANT SAFETY INSTRUCTIONS When using electrical appliances, basic safety precautions should be followed, including the following: WARNING - To reduce the risk of electrical shock, fire or injury to persons: • Read all instructions before using the unit. • Use only a 220-240 volt outlet. • Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened. • Periodically remove dust from the power plug.
IMPORTANT SAFETY INSTRUCTIONS CAUTIONS CONCERNING OPERATION INSTALLATION GUIDELINES • During the operation of the product, please place the unit at least 2 m away from equipment which are subject to electrical waves such as televisions, radios or wave clocks. • Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. • Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur.
PART NAMES MAIN UNIT DISPLAY POWER ON/OFF Button Plasmacluster ON/OFF Button Fan Speed Button P C Fan Speed Indicator Lights Odour Senser Plasmacluster Ion ON/OFF Indicator Light ILLUSTRATIVE DIAGRAM Odour Sensor Main Unit HEPA Filter (blue/white) Washable Active Carbon Filter (black) Filter Support Front Panel E-4 FU-W28E.eng.indd 6 08.11.
Plasmacluster Indicator Light(blue) Blue : Plasmacluster ON Light off : Plasmacluster OFF CLEAN - SIGN Light Clean Green Slightly Impure Orange Very Impure Red ENGLISH The colour changes according to the air condition. BACK INCLUDED • Operation manual Handle Air Outlet Date Label Power Cord Plug (Shape of plug depends on country.) E-5 FU-W28E.eng.indd 7 08.11.
PREPARATION Be sure to remove the power plug from the wall outlet. FILTER INSTALLATION To maintain the quality of the filters, they are installed in the main unit and packed in plastic bags. Be sure to remove the filters from the plastic bags before using the unit. 11 Front Panel Remove the filters 1 Remove the Front Panel. Pull the bottom of the Front Panel. 2 Remove the Filter Support. Pinch the two tabs and lift to remove. Up side Tabs Tabs the Active Carbon 3 Remove Filter and HEPA Filter.
22 Install the filters Tab the HEPA Filter 1 Place within the main unit with HEPA Filter the tabs facing up. Do not install the filter backwards or the unit will not operate properly. the Active Carbon 2 Place Filter on top of the HEPA Tabs Filter. Tabs ENGLISH Make sure that the tab of the HEPA Filter remains visible. Active Carbon Filter the bottom side tabs of the Filter Support into the associated holes of the main unit. 3 Insert Next push the upside tabs into the main unit.
OPERATION MAIN UNIT OPERATION F P P C Fan Speed Indicator Lights Plasmacluster Indicator Light Plasmacluster ON/OFF Indicator Light Power ON/OFF Button • Press to start operation (short beep) and stop operation (long beep) • Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off. • Unless the power cord has been unplugged, the operations starts in the previous mode it was operated in. Fan Speed Button • The operation mode can be switched as below.
Fan Speed Button Plasmacluster ON/OFF Button POWER ON/OFF Button CLEAN - SIGN Light The colour changes according to the air condition. Clean Green Slightly Impure Orange Very Impure Red ABOUT THE CLEAN-SIGN •The condition of the CLEAN-SIGN depends on the room air condition detected by the Odour Sensor when the plug is inserted into the wall outlet. •It is possible to have a green CLEAN SIGN if there are impurities in the are when the product is first turned on.
CARE AND MAINTENANCE To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result. MAIN UNIT Care Cycle 1 month To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
WASHABLE ACTIVE CARBON FILTER CARE WASHABLE ACTIVE CARBON FILTER CARE HAND WASH ONLY! DO NOT TUMBLE DRY! Care Cycle We recommend replacing the active carbon filter every six months. Clean the filter as offen as necessary when odour persists. Dry filter completely in a well ventilated a large container with 5 area. If possible, dry outdoors. 1 Fill lukewarm water, add a mild kitchen detergent and stir. the filter to soak ap2 Allow proximately 10 minutes .
CARE AND MAINTENANCE FILTER REPLACEMENT GUIDELINES Depending on the usage environment, air outlet odour may become strong after several months. If dust or odour cannot be removed easily, replace the filters.
TROUBLESHOOTING Before calling for repair, please review the list below, since the problem may not be a unit malfunction. REMEDY (not a malfunction) Odours and smoke are not removed. • Clean or replace the filters if they appear to be heavily soiled. (Refer to E-11,E-12) The CLEAN-SIGN Light lights green even when the air is impure. • The air could be impure at the time the unit was plugged in. (Refer to E-5) Pull out the plug from the electrical outlet, and insert the plug one minute later.
SPECIFICATIONS Model Power supply Fan Speed Adjustment Fan Rated Power Speed Operation Fan Speed Recommended Room Size High density Plasmacluster ion applicable floor surface Cord Length Dimensions Weight FU-W28E 220-240V 50/60Hz MAX 33W 168m3/hour MED 12W 90m3/hour SILENT 3.9W(3.5W) *1 30m3/hour ~21m2 *2 ~10m2 *3 2.0m 410mm(W)x158mm(D)x430mm(H) 4.3kg *1 Numbers in parentheses indicate the power consumption when the Plasmacluster indicator light and the CLEAN-SIGN light are off.
A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.
Memo FU-W28E.eng.indd 18 08.11.
ENGLISH FU-W28E.eng.indd 19 08.11.
SHARP CORPORATION OSAKA, JAPAN Printed in China TINS-A302KKRZ FU-W28E.eng.indd 20 08L 08.11.