12 Components
MX1 Reference Guide E-EQ-MX1RG-D
Installation
Figure 1-9 Connect Handle to MX1
In one hand grasp the MX1 unit so that the keypad is facing up and the endcap away from you. In
the other hand grasp the pistol-grip by the handle with the u-shaped cradle up and the trigger
mechanism away from you.
Place the pistol-grip handle u-shaped cradle under the MX1 unit and align the slots (2) on the
upper ends of the u-shaped cradle with the tabs (1) in the slots on the sides of the MX1 unit. Press
the MX1 unit into the u-shaped cradle until one of the tabs slides into the slot. Press the other tab
slot over the other tab until you feel a positive catch. You should hear a “click” as the units join.
Cautiously test the handle and unit to ensure proper, secure installation.
Removal
Insert a strong, flat object into one of the slots and gently pry the u-shaped cradle away from the
MX1 unit. Do not drop the MX1 unit. Once the pistol-grip handle is no longer secured to the MX1
unit pull the handle directly away from the unit. Do not slide the unit in the u-shaped cradle since
that may damage the contacts of either the handle or the unit.
Use and Operation
The pistol-grip handle enables the user of the MX1 to hold the unit while pointing and activating
the scanner with one hand. Pressing the trigger activates the scanner and functions the same as the
SCAN key on the keypad. With the handle installed the SCAN key on the keypad remains active.
The trigger duplicates the operation.