Service manual

AR-M236/M276/M237/M277 SIMULATION 8 - 8
Note: Executable only when the finisher is installed.
Operation/procedure
1. Touch the operation item to be set.
2. Enter the set value with the 10-key.
Note: Executable only when the finisher is installed.
Operation/procedure
Select item "1," and press the [START] key.
The shifter is reciprocated continuously at the specified interval.
[Selection 2]
1. Select item "2," and press the [START] key.
2. Move the shifter to the home position or in one way by the speci-
fied steps with the following keys.
A4R 5 6
WLT 2 1
LT 2 8
LG 4 4
FC 4 5
LTR 4 7
8K 6 11
16K 6 12
3-7
Purpose Adjustment
Function (Purpose) Used to adjust the offset tray operations.
Section Finisher
Item Operation
Item Content
Installation
range
Default
1 PAPER PUSH
TMG
Paper holder
descending timing
in non-staple
34-66 50
Used to adjust the descending timing of
the paper holder lever before lift-up
operation after paper exit or offset
operation. (The paper holder lever
prevents against paper shift in paper top
surface detection and paper stacking .)
2 PAPER OUT
DOWN
Tray descending
distance after non-
staple paper exit
0-12 1
Used to adjust the offset tray descending
distance after non-staple paper exit.
The descending distance is the relative
distance from the non-staple standby
position.
3 STAPLE UP Tray lift distance
before staple paper
exit
0-12 6
The height of the tray standby position in
stapling is changed for that in non-stapling
to improve stacking capacity in stapling.
(The relative distance for the height of the
tray standby position in non-stapling is
set.)
4 STAPLE DOWN Tray descending
distance after staple
paper exit
0-12 6
Used to adjust the offset tray descending
distance after staple paper exit.
The descending distance is the relative
distance from the non-staple standby
position.
Paper size
Side guide plate
adjustment value number
Adjustment value number
of the rear edge guide
plate
5 OFFSET INI.POS Offset tray shift
position adjustment
0-99 13
Used to shift the offset tray to the shipment
position or the disassembly position.
The offset tray is shifted to the specified
counter position.
(In the case of 0 - 94 (Shipment position)
1) Initialize the offset tray normally.
2) The tray descends to the parameter
position + 1 pulse position.
3) The tray lifts up to the specified param-
eter position.
(Disassembly position: 94 - 99)
1) The tray descends to the bottom.
* If there is some paper in the offset tray,
the tray cannot descend to the specified
position. Check to insure that there is no
paper in the tray before execution.
3-11
Purpose Operation test/check
Function
(Purpose)
Used to check the shifter operation.
Reciprocating operations are continuously performed
or the home position is checked. (The shifter is shifted
to the home position or moved in one way by the
specified steps.)
Item Operation
Item Content
1 F-R Reciprocating operation
2 HP CHECK Home position check
[*] key Shifts the position toward R side by the specified steps.
[0 key Shifts the position toward HP side by the specified steps.
[#] key Shifts to F.
SFTHP Shifter home position (At detection, highlighted)
Item Content
Installation
range
Default