Service manual

3-3
CHAPTER 3 INSTALLATION
III. PRINTER INSTALLATION INSTRUCTIONS
Install the printer in a location where the following temperature and humidity are met:
Ambient temperature: 10 - 32˚C
Ambient humidity: 20 - 80 %RH(Relative humidity)
Max. wet-bulb temperature: 25˚C
Use caution to avoid dew condensation.
If the printer is installed in a location with ambient relative humidity below 30%, use a
humidifier or antistatic mat.
Installation space
Place the printer on a flat desk large enough to accommodate its footings.
Provide ample spaces around the printer.
Plan view
Side View
60cm
20cm
20cm
100cm
60cm
20cm
20cm
100cm
70cm70cm