PRIMERGY PRIMERGY RX100 S4 Server Options Guide Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.
Comments… Suggestions… Corrections… The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs. Fax forms for sending us your comments are included in the back of the manual. There you will also find the addresses of the relevant User Documentation Department.
Contents 1 1.1 1.2 1.3 Introduction . . . . . . . . . Overview of the documentation Extensions and conversions . . Notational conventions . . . . 2 Procedure 3 Safety notes . . . . . . . . . . . . . . . . . . . . . . . . . . 11 4 4.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . Opening the server . . . . . . . . . . . . . . . . . . . . . . . 17 17 5 5.1 5.2 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . Equipping rules . . . . . . . . . . . . . . . . . . . .
1 Introduction The PRIMERGY RX100 S4 server is an Intel-based server for small and medium-sized networks. The compact server casing (only one height unit) as well as its scalability and security features make the PRIMERGY RX100 S4 the perfect choice for operational areas data centers, Internet- and applicationhosting. 1.1 Overview of the documentation I PRIMERGY manuals are available in PDF format on the ServerBooks CD which is supplied in the ServerView Suite package for every server system.
Overview of the documentation Introduction – “RX100 S4 Server Operating Manual” (PDF file available on the ServerBooks CD) – Technical Manual for the system board D2532 (PDF file available on the ServerBooks CD) – “BIOS Setup” manual (PDF file available on the ServerBooks CD) – “ServerView Suite” includes the ServerStart CD, the ServerBooks CD and the print version of the manual “PRIMERGY ServerView Suite - ServerStart”. The PDF file of the manual is also available on the ServerBooks CD.
Extensions and conversions Introduction 1.2 Extensions and conversions The PRIMERGY RX100 S4 server is offered in a SATA and a SAS version. The versions differ in the chipset assembling of the system board and in the configuration of the hard disks. Extension of the main memory The four slots for the main memory are suitable for unbuffered DDR II 533 (PC2-4200) SDRAM memory modules. The organization in two memory banks, 1 and 2, permits rapid memory access with two-way interleaving.
Notational conventions 1.3 Introduction Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands, menu items or software programs. „Quotation marks“ indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown. V CAUTION! pay particular attention to texts marked with this symbol.
2 Procedure V CAUTION! The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by service personnel. Any unauthorized opening and improper repairs could expose the user to risks (electric shock, energy hazards, fire hazards) and could also damage the equipment. Please note that any unauthorized opening of the device will result in the invalidation of the warranty and exclusion from all liability.
3 Safety notes I The following safety notes are also provided in the “Safety notes and other important information” manual. This device complies with the relevant safety regulations for data processing equipment. If you have any questions about where you can set up the device, contact your sales outlet or our customer service team. V CAUTION! The actions described in these instructions should only be performed by technical specialists. Equipment repairs should only be performed by service personnel.
Safety notes Installation and operation V CAUTION! 12 ● If the server is integrated in an installation that receives power from an industrial (public) power supply network with the IEC309 connector, the (public) power supply protection must comply with the requirements for the non-industrial (public) power supply networks for the type A connector. ● The server automatically sets itself to a voltage in the range of 100 V to 127 V or 200 V to 240 V.
Safety notes V CAUTION! ● Make sure that no objects (such as bracelets or paper clips) fall into or liquids spill into the device (risc of electric shock or short circuit). ● In emergencies (e.g. damaged casing, controls or cables, penetration of liquids or foreign matter), switch off the device immediately, remove the power plug and contact your sales outlet or customer service team.
Safety notes Batteries V CAUTION! ● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board under “Related publications” on page 47). ● Replace the lithium battery on the system board in accordance with the instructions in the technical manual for the system board (see “Related publications” on page 47).
Safety notes Note about the laser The CD-/DVD-ROM drive is classified for laser class 1according to IEC 60825-1. V CAUTION! The CD-/DVD-ROM drive contains a laser diode (LED). Sometimes the LED produces a stronger laser beam than laser class 1. Direct view into this laser beam is dangerous.
Safety notes ● Place all components on a static-safe base. I You will find a detailed description for handling ESD components in the relevant European or international standards (DIN EN 61340-5-1, ANSI/ESD S20.20).
4 Preparation V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . 4.1 Opening the server Ê Terminate all applications and shut down the server correctly. Ê If your operating system has not switched off the server, press the on/off button. Ê Pull all power connectors out of the power outlets. Ê Disconnect all cables on the rear of the server.
Opening the server Preparation Figure 3: Loosening the screws Ê Unlock the top cover by removing the knurled screw at the rear side. Ê Push the top cover approxiate 2 cm frontward. Ê Remove the top cover.
5 Main memory V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . The system board supports up to 8 Gbytes of main memory. Four slots (2 slots form a memory bank) are provided for the main memory. Each memory bank can be equipped with 512 Mbyte, 1 Gbyte or 2 Gbyte unbuffered DDR II 533 (PC2-4200) SDRAM memory modules. CPU Front Side Bus (FSB) Memory frequency 533 MHz (Celeron) 533 MHz 800 MHz 533 MHz 5.
Equipping rules Main memory The table below shows the order in which the memory banks must be equipped: Single-channel configuration Basic configuration DIMM_1A (black) DIMM_2A (blue) DIMM_1B (black) DIMM_2B (blue) Basic configuration with 1x memory module K987-Vxxx X - - - Additional memory module F3000 1x memory module: E513 E514 E515 Already populated by basic configuration - X - 2x memory module: E513 E514 E515 Already populated by basic configuration X X - 3x memory module: E513 E
Extending/replacing the main memory Main memory 5.2 Extending/replacing the main memory Ê Open the server as described in the chapter “Preparation” on page 17 et seq. . 2 1 1 Figure 5: Removing a memory module Ê Press the holders on either side of the mounting location concerned outward (1). Ê If the mounting location was already equipped: pull the memory module out of the mounting location (2).
Extending/replacing the main memory Main memory Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 37 et seq. .
6 Accessible drives V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . One 5.25-inch slimline bay is available for accessible drives. 6.1 Installing an accessible 5.25-inch slimline drive The 5.25-inch slimline drives available are CD-ROM and CD-RW/DVD drives. These drives can be installed in the free 5.25-inch slimline bay. Ê Open the server as described in the chapter “Preparation” on page 17 et seq. .
Installing an accessible 5.25-inch slimline drive Accessible drives V CAUTION! Keep the dummy cover for future use. If you remove the accessible drive again and do not replace it with a new one, the dummy cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures. Figure 8: Mounting frame Ê Push the 5.25-inch slimline drive in the mounting frame and fasten it with two screws on the left hand side (see arrows).
Accessible drives Installing an accessible 5.25-inch slimline drive Figure 9: Connecting the cables Ê Push the the mounting frame from the inside into the bay and fasten it with the knurled screw to the housing. Ê Connect the data cable to the accessible drive (see the cabling plans in the Appendix). Ê Connect the power cable connector P5 to the accessible drive (see the cabling plans in the Appendix).
7 Non-hot-plug hard disks V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . 7.1 Installing a second non-hot-plug SATA hard disk Ê Open the server as described in the chapter “Preparation” on page 17 et seq. . Figure 10: Removing the dummy cover Ê Remove the dummy cover from the bay. V CAUTION! Keep the dummy cover for future use.
Installing a second non-hot-plug SATA hard disk Non-hot-plug hard disks Figure 11: Inserting the new hard disk Ê Push the mounting frame with the new hard disk into the bay and fasten the mounting frame with a knurled screw (see circle) to the housing. Ê Connect the data cable to the hard disk (see the cabling plans in the Appendix). Ê Connect the power cable to the hard disk (see the cabling plans in the Appendix).
8 Controller in the PCI slots V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . The system board offers 2 x PCI-X (64 Bit / 133 MHz) or 1x PCI-Express x4 and 2 x PCI-X (64 Bit / 133 MHz) slots by a riser card. 8.1 Installing a controller Ê Open the server as described in the chapter “Preparation” on page 17 et seq. . Figure 12: Removing the riser card holder Ê Loosen the two knurled screws (see circles).
Installing a controller Controller in the PCI slots Ê If necessary, connect cables onto the controller. Figure 13: Riser card holder with riser card 1 Figure 14: Riser card holder with riser card 2 Ê Remove the PCI slot’s rear cover. V CAUTION! Keep the rear cover of the PCI slot for future use. If you remove the controller again and do not replace it with a new one, the rear cover must be reinstalled to comply with EMC regulations and to satisfy cooling requirements and fire protection measures.
Installing a controller Controller in the PCI slots Figure 15: Installing the riser card holder Ê Plug the riser card into the PCI slot of the system board. Ê Fasten the riser card holder with two knurled screws to the housing’s rear side. Ê If required, connect the cables to the system board or other components. Ê Close the server, connect it to the power outlet, and switch it on as described in the chapter “Completion” on page 37 et seq. .
9 Upgrade kit hot-plug variant V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . 9.1 Upgrading to hot-plug variant Ê Open the server as described in the chapter “Preparation” on page 17 et seq. . Figure 16: Removing the non-hot-plug hard disks Ê Remove the power connectors from the non-hot-plug hard disks. Ê Remove the Y-cable from the connector P4 of the power supply. Ê Remove the data cables from the non-hot-plug hard disk. Ê Loosen the knurled screws.
Upgrading to hot-plug variant Upgrade kit hot-plug variant Figure 17: SAS/SATA backplane The LED cable and the I2C cable are already connected to the SAS/SATA backplane. Figure 18: Installing the SAS/SATA backplane Ê Position the SAS/SATA backplane on the hooks (see circles). Make sure that the SAS/SATA backplane fits in the guidances (see arrows).
Upgrading to hot-plug variant Upgrade kit hot-plug variant Figure 19: Fastening the SAS/SATA backplane Ê Fasten the SAS/SATA backplane by pushing the green levels in direction of the arrows. Figure 20: Connecting cables Ê Connect the connector P4 of the power supply and the two SATA cables to the SAS/SATA backplane.
Upgrading to hot-plug variant Upgrade kit hot-plug variant Figure 21: Leading the cables Ê Thread the I2C cable and the LED cable through the separating plate (see arrow). Ê Connect the I2C cable to the connector CN17 on the system board. Ê Connect the LED cable to the connector CN11 on the system board. Ê Install the new hot-plug hard disks as described in the Operating Manual RX100 S4.
10 Completion V CAUTION! Observe the safety instructions in the chapter “Safety notes” on page 11 et seq. . 10.1 Closing the server Figure 22: Attaching the top cover Ê Position the top cover in such a way that it protrudes approxiate 2 cm at the rear. Ê Push the top cover all the way in direction to the front side. Ê Fasten the top cover with the knurled screw.
Closing the server Completion If you have not removed the server from the rack cabinet, please skip this page. Ê Push the server from the frontside in the extended telescopic rails. Ê Reconnect all the cables you disconnected beforehand on the rear of the server. 2 1 Figure 23: Installing the server in a rack cabinet Ê Press in the locking spring (1) on both sides and push the server as far as it will go into the rack. Ê Fasten the server in the rack using the two knurled screws (2).
11 Appendix 11.
Cabling Appendix A3C40071661 LED board P4 P1 CN15 CN13 CN26 CN17 CN25 P2 CN16 CN11 CN18 Fan 5 Fan 4 CPU Hot-plug hard disk 1 P5 Fan 3 CD-RW / DVD-RW Fan 2 CN19 Hot-plug hard disk 1 A3C40071367 P3 A3C40081497 A3C40081497 Power supply unit Fan 1 CN22 CN20 IDE 1 A3C40068699 Legend: Power Control Data Figure 25: Cabling of the non-hot-plug variant 40 Options Guide RX100 S4
Abbreviations AC Alternating Current ANSI American National Standard Institut ASR&R Automatic Server Reconfiguration and Restart BIOS Basic Input-Output System BMC CC Baseboard Management Controller Cache Coherency CD Compact Disk CD-ROM Compact Disk-Read Only Memory CHS Cylinder Head Sector CMOS Complementary Metal Oxide Semiconductor COM CPU Communication Central Processing Unit DC Direct Current RX100 S4 Options Guide 41
Abbreviations DIMM DIP Dual Inline Memory Module Dual Inline Package DMA Direct Memory Access DMI Desktop Management Interface ECC Errror Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read-Only Memory EMC ElectroMagnetic Compatibility) EMP Emergency Management Port EPP Enhanced Parallel Port ESD ElectroStatic Discharge FPC Front Panel Controller FRU FSB GAM 42 Field Replaceable Unit Front Side Bus Global Array Manager Options Guide RX100 S4
Abbreviations GUI HDD Graphical User Interface Hard Disk Drive HSC Hot-Swap Controller I²C Inter-Integrated Circuit I/O Input/Output ICM Intelligent Chassis Management ID IDE Identification Intergrated Drive Electronics IOOP Intetelligent Organization of PCI iRMC integrated Remote Management Controller IRQ Interrupt Request Line LAN Local Area Network LBA LCD LUN Logical Block Address Liquid Crystal Display Logical Unit Number RX100 S4 Options Guide 43
Abbreviations LVD MMF Low-Voltage Differential SCSI Multi Mode Faser MRL Manually Retention Latch NMI Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PCI PDA Peripheral Component Interconnect Prefailure Detection and Analysing POST Power ON Self Test RAID Redundant Arrays of Independent Disks RAM Random Access Memory ROM Read-Only Memory RSB RTC RTDS 44 Remote Service Board Real Time Clock Remote Test- und Diagnose-System Options Guide RX100 S4
Abbreviations SAF-TE SCSI Accessed Fault-Tolerance Enclosures SAS Serial Attached SCSI SATA Serial ATA SBE Single Bit Error SCA Single Connector Attachment SCSI Small Computer System Interface SDDC SDR Single Device Data Correction Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log SMI System Management Interrupt SSU System Setup Utility SVGA USB VGA Super Video Graphics Adapter Universal Serial Bus Video Graphics Adapter RX100 S4 Options Guide 45
Related publications Manuals for PRIMERGY server systems are available as PDF files on the ServerBooks CD. The ServerBooks CD is part of the PRIMERGY ServerView Suite delivered with each server system. The current versions of the required manuals can be downloaded free of charge as PDF files from the Internet. The overview page showing the online documentation available on the Internet can be found via the URL: http://manuals.fujitsu-siemens.com.
Related Publications [13] PRIMERGY ServerView Suite ServerView Server management User Manual [14] PRIMERGY ServerView Suite RemoteView User Manual [15] ServerView RAID User Manual [16] PRIMECENTER Rack Technical Manual [17] DataCenter Rack Technical Manual [18] 19” Rack Technical Manual [19] LSI SATA Software RAID User Manual [20] LSI Logic MegaRAID SAS Software User’s Guide [21] LSI Logic MegaRAID SAS Device Driver Installation [22] Integrated RAID for SAS User’s Guide [23] Embedded SA
Index A accessible drives 7, 23 C cabling of the hot-plug variant cabling of the non-hot-plug variant 40 controller 7, 29 39 E ESD (devices sensitive to electrostatic discharge) 15 I information material 6 L light-emitting diode (LED) 15 lithium battery 14 M main memory 7, 19 meaning of the symbols 8 N non-hot-plug hard disk 27 notational conventions 8 note about the laser 15 R riser card 29 S SAS/SATA backplane 34 SATA hard disk drives 7 T target group 5 top cover 18, 37 RX100 S4 Options Guide 4
Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.
Fujitsu Siemens Computers GmbH User Documentation 81730 München Germany Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.
Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Computers. This new subsidiary of Fujitsu has been renamed Fujitsu Technology Solutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed. Please note that all company references and copyrights in this document have been legally transferred to Fujitsu Technology Solutions.