Configuring the SDC 8200 system
91
Configuring additional VIP units (VIP)
After initialization, the central unit determines one VIP unit. To configure
additional VIP units (up to a maximum of 50 consoles), proceed as follows:
From the central unit’s operating menu, choose “
Conference”, “VIP
and “
Set VIP” one after the other.
The list number 01 (list numbers are from 01 to 50) is highlighted in
black.
Choose the desired list number and press the ENTER key.
The placeholder (“
0000”) for the microphone number is highlighted in
black.
Enter the microphone number of the conference console which you
want to configure as VIP unit.
Press the ENTER key to save your setting.
Note!
If your conference and interpretation system is PC controlled, the set-
tings for the VIP units made on the central unit are overwritten by the
settings made in the software control.
If the conference system is reinitialized, the list of VIP units is deleted.
Deleting the list of VIP units (VIP)
You can delete the list of configured VIP units in order to configure other
conference consoles as VIP units.
From the central unit’s operating menu, choose “
Conference”, “VIP
and “
Clear VIP” one after the other.
The text “
Configuration will be overwritten. Continue?” is
shown on the display.
Press the ENTER key.
The list of VIP units is deleted.
Activating/deactivating the special rights of the VIP units (VIP)
You can activate (
ON”) or deactivate (“OFF”) the special rights of the VIP
units.
From the central unit’s operating menu, choose “
Conference”, “VIP
and “
Status” one after the other.
The current status (“
ON” or “OFF”) is shown on the display.
Change the status and press the ENTER key to save your setting.
The special rights of the VIP units are activated or deactivated.
Resetting the conference system (Reset)
To reset the conference system:
From the central unit’s operating menu, choose
Conference” and
Reset” one after the other.
Press the ENTER key.
The conference system is reset.
Note!
Resetting the conference system has no effect on the interpretation
system.
Set VIP
01 = 0000
Set VIP
01 = 0000
VIP
2 Clear VIP
VIP
3 Status
VIP
Status = ON
Press ENTER to Save
Conference
6 Reset