user manual

Table Of Contents
Operating the components of the SDC 8200 system
28
Turning interconnected SDC 8200 CU central units on/off
When turning on a conference and interpretation system with several
SDC 8200 CU central units, it is important that the central units are turned
on in the correct order.
First turn on the “master” central unit.
Then turn on the “slave” central units in the order in which they are
connected to the “master”.
To turn a central unit on:
Set the POWER switch to position “I”.
The consoles which are powered via this central unit are ready for oper-
ation as soon as they are initialized.
The start display is shown on the LC display of this central unit.
Note!
It is, however, possible to simultaneously turn on interconnected cen-
tral units via a switchable multiple socket.
To turn a central unit off:
Set the POWER switch to position “0”.
The display goes off. All consoles which were powered via this central
unit are also turned off.
Note!
The central units are not disconnected from the mains when they are
turned off. To disconnect the central units from the mains, pull their
mains plugs out of the wall outlets.
Operating the delegate units
Taking the floor / Making a request to speak
In order to take the floor or make a request to speak, you have to press the
microphone key . Depending on the conference mode chosen (1. to
10., see following section), you can either take the floor immediately or
you have to wait until your microphone is turned on.
>Volume =
P1 P2 P3 P4 P5 P6